background image

9

Precautions For Safe Use and             
Installation 

 

 

 
 

 

 

Disconnect all supply voltages before taking any action on the device. 

 

 

Do not disassemble the device when it is under power. 

 

 

Do not clean the device with solvents or similar substances. Use only dry cloth to clean 
the device. 

 

 

Check that the connections are correct before starting the device. 

 

 

Keep signal cables away from contactors, inductive loads and electrical noise-emitting 
devices and power-carrying lines. 

 

 

Mount  the  device  away  from  the  contactor,  electrical  noise  emitting  devices  and 
energy-transmitting  lines,  which  are  protected  against  adverse  environmental  con-
ditions such as humidity, vibration, pollution and high/low temperature. 

 

 

To minimize electrical noise, use shielded cable and ground the display 

 

 

Connect the power supply as shown on page 2. Otherwise, device the connection will 
be "out of warranty". 

 

 

Contact your seller for any questions on your device. 

 

 

 

The manufacturer shall not be liable in any way for any unwanted circumstances ari-
sing from the failure to perform the above precautions. 

 

IMPROVE PERFORMANCE WITH OUR TECHNOLOGY 

 

  USER GUIDE 2020 

UTC02

 Tension Control 

Summary of Contents for UTC02

Page 1: ...USER GUIDE 2020 UTC02 TENSION CONTROL DEVICE ...

Page 2: ...ng Diagram 3 Installation and Commissioning Flowchart 4 Device Key User Guide 5 Device Parameter 6 Precautions For Safe Use and Installation 9 Our Contact Information 10 UTC02 TR 2020 UNITY OTOMASYON Tüm Hakları Saklıdır IMPROVE PERFORMANCE WITH OUR TECHNOLOGY USER GUIDE 2020 UTC02 Tensıon Control ...

Page 3: ...ni mum Output Value Transmitter Mode Can Be Added Feature Operation Voltage 24V DC Break Output Voltage and Current 24Vdc 4A Operation Temperature 0 55 C Response Time 1 ms Connection Style Interlaced Terminal Groups Device Weight 500 gr Type of Mounting Panel Type Dimensions 177 x 113 x 125 G Y D Indicator 4 x 20 LCD Ekran Inputs Loadcell External Start External Value Set PSW Input For Machine St...

Page 4: ...2 GENERAL AND TECHNICAL FEATURES IMPROVE PERFORMANCE WITH OUR TECHNOLOGY USER GUIDE 2020 UTC02 Tension Control ...

Page 5: ...3 DEVICE CONNECTION and CABLE FLOWCHART IMPROVE PERFORMANCE WITH OUR TECHNOLOGY USER GUIDE 2020 UTC02 Tension Control ...

Page 6: ...eck Page 2 Mounting of input output and motor cables Check Page 2 Control of insulation of input and motor cables Mounting of power cables Check Page 2 Cable and Terminals Cont rol Mounting Control Parameter settings and operation of the device Check Pages 5 and 6 TASK 4 INSALLATION AND COMMİSSİONİG FLOWCHART IMPROVE PERFORMANCE WITH OUR TECHNOLOGY USER GUIDE 2020 UTC02 Tension Control ...

Page 7: ...irm changing values Operation For Tare The device must be in a stop position The roller should not be the material This key needs to be pressed for 5 seconds START ESCAPE ENTER 5 DEVİCE KEY USER MANUEL IMPROVE PERFORMANCE WITH OUR TECHNOLOGY USER GUIDE 2020 UTC02 Tension Control MENÜ UP DOWN STOP ESC TARE To exit the menu and reset the output voltage when the device is at Stop position Esc key 3 s...

Page 8: ...press and hold the Up arrow key to move forward 4 SET ADJUSTMENT CONTROL 4 SET ADJUSTMENT CONTROL PANEL Menu key 3 SEC press and hold the Up arrow key to move forward 6 DEVICE PARAMETERS IMPROVE PERFORMANCE WITH TECHNOLOGY USER GUIDE 2020 UTC02 Tension Control MENU MENU MENU MENU Press Enter to set the control position SET setting can be selected from the control terminal and panel By selecting th...

Page 9: ... values you can choose are 50 KG 100 kg 200 kg Press Enter to determine how it works Here you can choose from Loadcell Dancer and Manual If LOADCELL is selected the current tension is automatically controlled and the set value is set according to the load cell value If Manuel is selected the device output voltage is manually determined by pressing the push down buttons or external potency analog i...

Page 10: ...stop times with the arrow keys By pressing the tare button on the panel the we ight of the roller to which loadcell is connected is reset You can see this weight in the tare weight parameter ENTER tuşuna bir kere basınız MEVCUT GERGİNİN yanındaki 0 0 değeri yanıp sönmeye başlayacaktır Kilosu 5 kg olan bir yükü merdanenin ortasına asınız ve tekrardan ENTER tuşuna basınız 0 0 değeri yanıp sönme işle...

Page 11: ...e device away from the contactor electrical noise emitting devices and energy transmitting lines which are protected against adverse environmental con ditions such as humidity vibration pollution and high low temperature To minimize electrical noise use shielded cable and ground the display Connect the power supply as shown on page 2 Otherwise device the connection will be out of warranty Contact ...

Page 12: ...l Adress İkitelli Organize Sanayi Bölgesi Eskoop Sanayi Sitesi B 1 Blok No 59 61 63 İkitelli Başakşehir İstanbul Telephone 90 212 549 30 56 90 212 671 30 54 Faks 90 212 549 30 57 GSM 90 552 366 30 56 Mail info unityotomasyon com www unityotomasyon com 10 OUR CONTACT INFORMATION ...

Reviews: