background image

Bosch Security Systems | October 10, 2006

LTC 9349 Series | 

Instruction Manual

Safety Precautions

EN

| 3

For Indoor Product

1.

Water and Moisture

- Do not use this unit near

water - for example, in a wet basement, in an
unprotected outdoor installation or in any area
classified as a wet location.

2.

Object and Liquid Entry

- Never push objects of

any kind into this unit through openings, as they
may touch dangerous voltage points or short out
parts that could result in a fire or electrical shock.
Never spill liquid of any kind on the unit.

3.

Power Cord and Power Cord Protection

- For

units intended to operate with 230VAC, 50Hz, the
input and output power cord must comply with
the latest versions of IEC Publication 227 or IEC
Publication 245. 
Power supply cords should be routed so they are
not likely to be walked on or pinched. Pay
particular attention to location of cords and plugs,
convenience receptacles, and the point of exit
from the appliance.

4.

Overloading

- Do not overload outlets and

extension cords; this can result in a risk of fire or
electrical shock.

For Outdoor Product

Power Lines

- An outdoor system should not be

located in the vicinity of overhead power lines,
electric lights or power circuits, or where it may
contact such power lines or circuits. When
installing an outdoor system, extreme care should
be taken to keep from touching power lines or
circuits, as this contact might be fatal. U.S.A.
models only - refer to the National Electrical
Code Article 820 regarding installation of CATV
systems.

For Rack-Mount Product

1.

Ventilation

- This unit should not be placed in a

built-in installation or rack, unless proper
ventilation is provided, or the manufacturer’s
instructions have been adhered to. The equipment
must not exceed its maximum operating
temperature requirements.

2.

Mechanical Loading

- Mounting of the

equipment in a rack shall be such that a
hazardous condition is not achieved due to
uneven mechanical loading.

Safety Precautions

Attention: Installation should be performed by
qualified service personnel only in accordance
with the National Electrical Code or applicable
local codes.

Power Disconnect. Units with or without ON-OFF
switches have power supplied to the unit
whenever the power cord is inserted into the
power source; however, the unit is operational
only when the ON-OFF switch is in the ON
position. The power cord is the main power
disconnect for all units. 

CAUTION: TO REDUCE THE RISK OF
ELECTRIC SHOCK, DO NOT REMOVE COVER
(OR BACK). NO USER SERVICEABLE PARTS
INSIDE.  REFER SERVICING TO QUALIFIED
SERVICE PERSONNEL.

This symbol indicates the presence of
uninsulated “dangerous voltage” within the
product’s enclosure. This may constitute a
risk of electric shock.

The user should consult the operating and
maintenance (servicing) instructions in the
literature accompanying the appliance.

Summary of Contents for LTC 9349 Series

Page 1: ...LTC 9349 Series Unity Dome Instruction Manual EN Prepackaged Camera Line ...

Page 2: ...al shock or other hazards 9 Safety Check Upon completion of servicing or repairs to the unit ask the service technician to perform safety checks to ensure proper operating condition 10 Power Sources Operate the unit only from the type of power source indicated on the label If unsure of the type of power supply to use contact your dealer or local power company For units intended to operate from bat...

Page 3: ...ould be taken to keep from touching power lines or circuits as this contact might be fatal U S A models only refer to the National Electrical Code Article 820 regarding installation of CATV systems For Rack Mount Product 1 Ventilation This unit should not be placed in a built in installation or rack unless proper ventilation is provided or the manufacturer s instructions have been adhered to The e...

Page 4: ... con o sin interruptores de encendido apagado reciben alimentación eléctrica siempre que el cable de alimentación esté conectado a la fuente de alimentación Sin embargo la unidad sólo funciona cuando el interruptor está en la posición de encendido El cable de alimentación es la principal fuente de desconexión de todas las unidades PRECAUCIÓN PARA DISMINUIR EL RIESGO DE DESCARGA ELÉCTRICA NO RETIRE...

Page 5: ...a in funzione solo quando l interruttore ON OFF si trova nella posizione ON Il cavo di alimentazione costituisce il dispositivo di scollegamento dell alimentazione principale per tutte le unità ATTENZIONE PER RIDURRE IL RISCHIO DI SCOSSE ELETTRICHE NON RIMUOVERE LA COPERTURA O IL PANNELLO POSTERIORE L UNITÀ NON CONTIENE COMPONENTI INTERNI RIPARABILI DALL UTENTE PER QUALSIASI INTERVENTO RIVOLGERSI ...

Page 6: ... 8 4 1 Suspended Ceiling Mounting 8 4 2 Hard Ceiling Mounting 9 4 3 Connections for F Suffix and N Suffix Models 9 5 CAMERA SETUP 10 5 1 Camera Lens Positioning 10 5 2 Lens Vari focal Range Adjustment 10 5 3 Remote Video Setup 10 6 CAMERA LENS SETTINGS 11 6 1 Backlight Compensation White Balance Line Lock and Phase Settings 11 7 OPERATION 12 8 MAINTENANCE 12 9 SERVICE PARTS 12 10 DIMENSIONAL OUTLI...

Page 7: ...8 e mail BoschCCTVparts ca slr com Canada Phone 514 738 2434 fax 514 738 8480 Europe Middle East Asia Pacific Region Phone 44 0 1495 274558 fax 44 0 1495 274280 email rmahelpdesk solectron com For additional information see www boschsecurity com 3 DESCRIPTION In ceiling dome with integrated 1 4inch camera and varifocal lens See table below for description of various models Bosch Security Systems O...

Page 8: ...to ensure proper camera phasing On 12VDC units either wire can go to either quick connector on the camera b Connect the wires to the unit See FIGURE 2a for units supplied with white cameras and FIGURE 2b for units with black cameras To connect squeeze the end of the connector fully insert the stripped conductor into the square entry and release c Route and connect the video cable to the main video...

Page 9: ...n from each wire The quick connect wire connector is designed to accommodate wire gauge sizes from 1 5mm2 to 0 5mm2 16 20AWG NOTE On 24VAC units either wire can go to either quick connector on the camera In multiple camera installations connect the wires to the same connectors to ensure proper camera phasing On 12VDC units either wire can go to either quick connector on the camera b Connect the wi...

Page 10: ...ght after completing camera positioning 5 2 Lens Varifocal Range Adjustment These models are provided with either a 3 8mm or 5 50mm varifocal DC auto iris lens Adjust focal range to obtain desired view as you would with any varifocal type lens 5 3 Remote Video Setup This section descibes camera adjustments that may be necessary prior to final installation 1 After completion of power and video conn...

Page 11: ...Control The phase may be adjusted as required by using a small blade screwdriver Figure 5a Location of Camera Lens Settings White Camera Figure 5b Location of Camera Lens Settings Black Camera The control functions and settings described below are shown in the same sequence as they appear in FIGURE 6 Phase Control V V P P H H A A S S E E Vertical Phase Adjustment Default Dip Switch Settings Color ...

Page 12: ...omobiles such as Megular s Mirror Glaze Cleaner Wax 6 is acceptable 9 SERVICE PARTS Description Part No Dome Bubble 315 4054 001 B W Camera LTC 0135MC B W Camera HiRes LTC 0155MC Color Camera LTC 0235MC Color Camera Hi Res LTC 0255MC 3 8mm Varifocal Lens LTC 3364 32 5 50mm Varifocal Lens LTC 3374 20 Charcoal Trim Ring 315 3133 004 Adaptor Ceiling Ring 315 3660 003 10 DIMENSIONAL OUTLINE Figure 7 D...