P
P
P
Product
roduct
roduct
roduct M
M
M
Manual
anual
anual
anual
NO. :J
G19-C0022
REV
:
R1.0
DATE
:
2019-3-23
Security rating:□Top secret□ Confidential □Secret□ Ordinary
4.
4.
4.
4.Characteristic curve
Characteristic curve
Characteristic curve
Characteristic curve
0
20
40
60
80
100
10.0
10.5
11.0
11.5
12.0
12.5
13.0
13.5
14.0
14.5
Capacity(Ah)
V
o
lt
a
g
e
(V
)
Discharge
Charge
12.8V100Ah Charge-Discharge Curve 0.2C,25
0
C
5.
5.
5.
5. Standard T
Standard T
Standard T
Standard Test Conditions
est Conditions
est Conditions
est Conditions
Battery test must be within 1 month after production.
All tests in this specification should be in standard atmospheric conditions:
temperature: 25±2℃, relative humidity: 65±20%
5.1
5.1
5.1
5.1 Standard charge
Standard charge
Standard charge
Standard charge
Charge the battery with Lithium ion battery special test cabinet, supply standard voltage(14.4±0.15V),
standard current(20A) until current down to 1-2A.
5.2
5.2
5.2
5.2 S
S
S
Standard discharge
tandard discharge
tandard discharge
tandard discharge
Discharge the battery with standard current(20A) on special test device, constant discharge to standard
discharge voltage(10V).
5.3
5.3
5.3
5.3 Electrical Performance
Electrical Performance
Electrical Performance
Electrical Performance
Test Items
Test Methods
Test Standards
capacity
retention rate
Standard charging , in standard test conditions on hold for 28
days ,standard discharge .
capacity retention
rate≥ 80%
6666.... Cautions
Cautions
Cautions
Cautions
Please pay attention to followings in case of battery will have leakage, heat etc.
Do not immerse the battery in water or seawater, and keep the battery in a cool dry surrounding if it