Proper Operating Environment
7
Detail
Note:
The following diagram shows a typical exhaust system layout. Use this as a guideline for proper
exhaust system installation. Although this diagram serves as an example, we recommend you consult
with a licensed contractor to meet local safety, environmental and building code requirements and to
also calculate the correct size blower required for your particular installation. Length of exhaust pipe,
exhaust pipe diameter, number of 90-degree angles and other restrictions must be calculated when
determining the correct exhaust blower unit. Installing an undersized or oversized blower is not only
unsafe, but can also lead to excessive wear and tear to the laser system and premature failure.
ILS9.75, ILS9.150D, ILS12.75 and ILS12.150D
Exhaust blower mounted outside* (User Supplied)
1.
Weatherproof shield (User Supplied)
2.
Rigid ducting matching the diameter of the blower inlet (User Supplied
3.
Adapter to the hose reduces from 4” to 3” (User Supplied)
4.
Y-pipe (User Supplied)
5.
Shut-off or air-flow gate(s) (User Supplied)
6.
Flexible, wire-reinforced, industrial grade rubber hose (User Supplied)
7.
Connection to laser system
8.
Exhaust On/Off switch (User Supplied)
9.
Computer (User Supplied)
10.
*Exhaust blower illustration my differ according to your region.