Controls:
The ULS Computer Controlled Compressed Air Unit functions automatically when connected the laser system
and no operator intervention is necessary. Controls and indicators on the unit are for diagnostics and provide
the following information:
Link light – blinks to indicate good communications link with the laser system
ON and OFF lights – indicate the state of the compressor. If the ON light is illuminated the compressor
should be running and supplying compressed air. If the OFF light is illuminated the compressor should be
off and no compressed air is being supplied.
Manual ON/OFF switch – turns compressor on or off manually to verify operation.
Maintenance
The particle filter should be inspected every 8 to 16 hours of use. Clean out the filter as necessary. The filter can
be inspected by unscrewing the lower bell shaped portion of the filter housing (1/8 turn) and removing the red
foam filter found inside. If it needs cleaning, wash it in water, dry it thoroughly and reassemble.
89
Air
Compressor
Gas
CONTROL
WIRE
Computer Controlled
Air Assist
BLUE COILED HOSE
FILTER
FITTING
OFF
BLUE COILED HOSE
LINK
INPUT
POWER
ON
MANUAL
ON/OFF
SWITCH
COMMUNICATION
PORT
Summary of Contents for PLS4.75
Page 1: ...PLS User Guide PLS4 75 PLS6 75 PLS6 150D PLS6MW www ulsinc com Revision August 2012...
Page 5: ...Chapter 1 Specifications 5...
Page 8: ...Chapter 2 Safety 8...
Page 14: ...Tamper Proof Labels Safety Labels...
Page 15: ...ULS Fiber Laser Cartridge Labels 15...
Page 16: ......
Page 17: ...PLS4 Back View 17...
Page 18: ...PLS6 Front View 18...
Page 19: ......
Page 22: ...Chapter 3 Installation 22...
Page 40: ......
Page 48: ...Chapter 4 Operation 48...
Page 83: ...Chapter 5 Accessories 83...
Page 99: ...Example Connection for PNP mode Example Connection for NPN mode 99...
Page 111: ...Chapter 6 Maintenance 111...
Page 119: ...www ulsinc com...