Goodrive10 inverters Function codes
62
Function
code
Name
Detailed instruction of parameters
Default
value
Modify
P10.14
Multi-stage
speed 6
When S1=S2=S3=S4=OFF, the frequency input manner is
selected via code P00.06 or P00.07. When all
S1=S2=S3=S4 terminals aren’t off, it runs at multi
-stage
which takes precedence of keypad, analog value,
high-speed pulse, PLC, communication frequency input.
Select at most 16 stages speed via the combination code of
S1, S2, S3, and S4.
The start-up and stopping of multi-stage running is
determined by function code P00.06, the relationship
between S1,S2,S3,S4 terminals and multi-stage speed is
as following:
S1
OFF ON OFF
ON OFF ON OFF ON
S2
OFF OFF ON
ON OFF OFF ON ON
S3
OFF OFF OFF
OFF ON ON ON ON
S4
OFF OFF OFF
OFF OFF OFF OFF OFF
stage 0
1
2
3
4
5
6
7
S1
OFF ON OFF
ON OFF ON OFF ON
S2
OFF OFF ON
ON OFF OFF ON ON
S3
OFF OFF OFF
OFF ON ON ON ON
S4
ON ON ON
ON ON ON ON ON
stage 8
9
10
11
12
13
14
15
Setting range of P10.(2n,1<n<17): -100.0~100.0%
0.0%
○
P10.16
Multi-stage
speed 7
0.0%
○
P10.18
Multi-stage
speed 8
0.0%
○
P10.20
Multi-stage
speed 9
0.0%
○
P10.22
Multi-stage
speed 10
0.0%
○
P10.24
Multi-stage
speed 11
0.0%
○
P10.26
Multi-stage
speed 12
0.0%
○
P10.28
Multi-stage
speed 13
0.0%
○
P10.30
Multi-stage
speed 14
0.0%
○
P10.32
Multi-stage
speed 15
0.0%
○
P11 Group Protective parameters