To carry out a manual setup of devices, tap the Sync button on the 
controller. To exit the inclusion mode on the controller, tap the 
Sync button again. To exclude a Z-Wave product from the network, 
hold the Sync button down for 3 seconds. (Figure 2-1)

 
WPS Button

 

Easy push button inclusion for Wi-Fi devices.

 

(Figure 2-1)

 
Reset Button

 

The URC controllers can be reset to factory defaults by 
holding the reset button for 20 seconds and releasing it. This will 
reset the Z-Wave network and change it’s House ID, and clear your 
account and user configuration data from your controller.

The account will only be removed from the controller, but it will 
continue to be in the database.

Holding the reset button for 10 seconds will reset the network 
configuration settings to defaults, while keeping your other 
settings intact. (Figure 2-1)

Note: 

If this controller is the primary controller for your network, 

resetting it will result in the nodes in your network being orphaned and 
it will be necessary after the reset to exclude and re-include all of the 
nodes in the network.  If this controller is being used as a secondary 
controller in the network, use this procedure to reset this controller 
only in the event that the network primary controller is missing or 
otherwise inoperable.

A

B

C

Figure 2-1:

 TRF-ZW2 Side

A

B

C

Service

Z-Wave

Wi-Fi

WAN

Power

Summary of Contents for TRF-ZW2

Page 1: ...i TRF ZW2 Z Wave Gateway Owner s Manual ...

Page 2: ...ERSAL REMOTE CONTROL INC SHALL NOT BE LIABLE FOR OPERATIONAL TECHNICAL OR EDITORIAL ERRORS OMISSIONS MADE IN THIS MANUAL The information in this manual may be subject to change without prior notice URC Control the Experience is a registered trademark of Universal Remote Control Inc Total Control is a registered trademark of Universal Remote Control Inc All other brand or product names are trademar...

Page 3: ...RES AND BENEFITS 2 PACKAGE CONTENTS 3 DEVICE LAYOUT 4 INSTALLATION 6 USING THE TRF ZW2 7 RESTRICT INSTALLER OFFSITE ACCESS 8 HARDWARE SPECIFICATION 9 LIMITED WARRANTY STATEMENT 10 END USER AGREEMENT 12 FEDERAL COMMUNICATIONS COMMISSION COMPLIANCE STATEMENT 13 ...

Page 4: ... it s uses and applications visit the TRF ZW2 s product web page Programmable only by a URC Certified Professional Custom Integrator To fully control and automate your system your professional custom integrator must have detailed knowledge of each component the local area network LAN architecture as well as Wi Fi configuration and other system connections Once configured to operate with your URC c...

Page 5: ...more information visit the Z Wave alliance web site Improved performance features include Improved battery life for Z Wave devices not connected to a power source Improved range creates a more robust network and reduces the need for Z Wave repeaters Provides more than twice the bandwidth Network wide inclusion pairing allows for easier installation and expansion Enhanced self healing for improved ...

Page 6: ...of the most popular products available in today s marketplace Wi Fi Enabled Wi Fi connectivity allows for optimized placement and simplified installation Package Contents What s Included with your new product TRF ZW2 Z Wave Extender 12V Power Adaptor Ethernet Cable Warranty Card If any of these items are missing contact URC s Technical Support Department at 914 835 4484 3 ...

Page 7: ...wer Receptacle connects to the included DC adapter Ethernet Port bridges the TRF ZW2 and your local area network LAN USB Port provides features and support for advanced applications 4 12V Power Receptacle RJ 45 Ethernet Port USB Port ...

Page 8: ...isabled Flashing Slowly Unit in Include Pairing Mode Flashing Quickly Unit in Exclude Unpairing Mode Wi Fi LED On Wi Fi enabled Off Wi Fi disabled Flashing Indicates traffic over Wi Fi WAN LED On Ethernet is connected Off Ethernet is disconnected Flashing Indicates traffic over ethernet Power LED On Power on normal operation Off Power off Flashing Booting firmware upgrade Z Wave LED Wi Fi LED WAN ...

Page 9: ...he supplied network Ethernet cable to connect the TRF ZW2 s Ethernet port to your local area network router or network switch Connect the supplied DC adapter to the TRF ZW2 and plug the adapter into an AC receptacle Upon power up the TRF ZW2 checks for an available firmware upgrade If an upgrade is available it is installed automatically The update process takes 15 minutes or less and is indicated...

Page 10: ... manually Including a device 1 To include your Z Wave devices press the Sync button once The Z Wave light blinks slowly once every second to indicate that it is in inclusion pairing mode 2 Follow the pairing unpairing instructions for the Z Wave device devices have manufacturer specific instructions 3 When paired successfully the TRF ZW2 s Z Wave LED flashes rapidly for less than a second then ret...

Page 11: ...ing in for the first time using the temporary password e mailed to the address you provide your installer the initial Setup Wizard gives you the option to restrict installer access Installer access can be restricted at any time by following the steps below Log into your user account at www urc mios com Select Settings from the column of options at left Choose Customer Care from the expanded list o...

Page 12: ... NAND 128MB Memory DDR2 128MB USB Port 1 WAN Port 1 Wireless Z Wave Plus and 802 11 a b g n Wi Fi Dimensions 4 55in x 3 13in x 1 2in HxWxD Weight 12 oz shipping weight Certifications FCC CE RoHS Z Wave Plus Power Supply Input AC 100 240VAC 50 60Hz Output DC 12V 1A 9 ...

Page 13: ...SIONS MADE IN THE URC DOCUMENTATION URC DOES NOT WARRANT THAT THE URC SOFTWARE IS BUG FREE OR ERROR FREE OR THAT THERE ARE NO ERRORS BUGS IN THE URC SOFTWARE URC warrants that at the time of purchase the URC equipment and the URC software complied with all applicable regulations and policies of the Federal Communications Commission FCC regarding electromagnetic interference caused by electronic co...

Page 14: ...tion to URC at 420 Columbus Avenue Valhalla NY 10595 It is end user s responsibility to backup any macro programming artwork software or other materials that may have been programmed into the unit It is likely that such data software or other materials will be lost during service and URC will not be responsible for any such damage or loss A dated purchase receipt bill of sale installation contract...

Page 15: ...ENT SHALL URC BE LIABLE FOR THE ACTS OR OMISSIONS OF END USER OR ANY THIRD PARTY THE LIMITATIONS OF LIABILITY MAY NOT APPLY TO END USER IN WHOLE OR IN PART WHERE SUCH ARE RESTRICTED LIMITED OR EXCLUDED BY APPLICABLE LAW AND SUCH SHALL APPLY TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW URC SHALL NOT BE HELD RESPONSIBLE FOR THE STATEMENTS MADE BY OTHERS SOME STATES OR JURISDICTIONS DO NOT ALLOW...

Page 16: ...s Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment to an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help Warning Changes or modifications not expressly approved by the manufacturer could void the user s authority to operate the equi...

Page 17: ...14 Notes ...

Page 18: ...500 Mamaroneck Avenue Harrison NY 10528 Phone 914 835 4484 Fax 914 835 4532 www universalremote com TRF ZW2_OM_final_12 08 15_REV5_RH ...

Page 19: ...TRF ZW2 Controller Z Wave Overview Guide ...

Page 20: ... before adding with your TRF ZW2 You may also need to do this if you have problems Inclusion Exclusion the first time Press the Retry button to start the exclusion process Once the device is excluded add it by following the inclusion steps Select Devices and click on the Add Device option Click on the sign for the device s category A list of URC Custom Device Wizards is displayed Select a device t...

Page 21: ... ZW2 You may also need to do this if you have problems Inclusion Exclusion the first time Press the Retry button to start the exclusion process Once the device is excluded add it by following the inclusion steps Select Devices and click on the Add Device option Click on the sign for the Other Device s category A list of URC Custom Device Wizards is displayed If your specific device is not shown se...

Page 22: ... from your controller The account will only be removed from the controller but it will continue to be in the database Holding the reset button for 10 seconds will reset the network configuration settings to defaults while keeping your other settings intact Figure 2 1 Note If this controller is the primary controller for your network resetting it will result in the nodes in your network being orpha...

Page 23: ... Select the Advanced tab Figure 3 1 From there you ll be able to access these Advanced Z Wave options Reset Z Wave network Will clear all the user configuration data and assign a new Z Wave HouseID Copy Z Wave network from a primary controller Will allow the unit to copy all Z Wave related information from a Primary Z Wave Controller and is used with Replication Controller shift Tells URC to trans...

Page 24: ... existing Z Wave network Steps for TRF ZW2 controller using the web interface Click on Settings Z Wave Settings Advanced Select Copy Z Wave network from a primary controller This will put the controller into learn mode and shift it to a secondary role The controller can now receive data from a primary device in the network and associate with other devices in the Z Wave network via the primary cont...

Page 25: ...within the network will act as repeaters regardless of the vendor to increase the reliability of the network Support for sending Z Wave Commands Z Wave commands can be sent using the TRF ZW2 API which will allow you to send HTTP requests with the specified command class to the specified node More details can be found on our wiki page http wiki mios com index php Luup_UPnP_Variables_and_Actions ZWa...

Page 26: ......

Reviews: