Operation

Operating the drill

 

This 1/2" Reversible Pistol Grip Drill is designed to operate 
on 90 PSIG. Lower pressure (below 90 PSIG) will reduce 
performance of the tool. Higher air pressure (over 90 
PSIG) raises the performance of the tool beyond its rated 
capacity and could cause serious damage to tool and user.

Changing the rotation direction

 

The direction of the bit rotation is reversible. 

 

Control the rotation direction by moving the side-mounted 
switch to F (forward) or R (reverse) as required for the 
operation.

Installing and removing the bits

WARNING:

 Disconnect tool from air supply before servicing 

or changing accessories.

To install the bits:

 

Remove the air supply from the reversible drill. 

 

Insert the drill bit as far as possible into the opening. 

 

Using an appropriately sized chuck key, turn the chuck key 

clockwise to securely tighten the drill bit, tap, or reamer in 

the drill chuck.

 

Always remove the chuck key before connecting the drill to 
the air line.

To remove the bits:

 

Remove the air supply from the reversible drill.

 

Using an appropriately sized chuck key, turn the chuck key 

counterclockwise to loosen the drill bit, tap, or reamer in 

the drill chuck.

 

Remove the bit.

 

Drilling

  Place the rotation direction forward position.  

 

  Hold the drill with one hand.
  Place the bit head onto the surface and slowly depress the 

switch trigger. Start the bit slowly for more control.

Summary of Contents for UT2855R

Page 1: ...atic tool TABLE OF CONTENTS General Safety Information 2 Air Compressor and Air Tool Safety 2 3 Tool Specifications 3 Installation 4 Maintenance Lubrication 4 Operation 5 Troubleshooting 6 Warranty 6 Service Parts 7 WARNING This product contains chemicals known to the State of California to cause cancer and birth defects or other reproductive harm Wash hands after handling WARNING This product con...

Page 2: ... used in a dust filled environment exhaust air can cause a dust hazard Dusts and fumes generated when using power tools can cause ill health for example cancer birth defects asthma and or der matitis risk assessment of these hazards and implementation of appropriate controls of is essential Risk assessment should include dust created by the use of the tool and the potential for disturbing existing...

Page 3: ...from those exposures varies depending on how often you do this type of work To reduce your exposure to these chemicals work in a well ventilated area and work with approved safety equipment such as dust masks that are specifically designed to filter out microscopic particles Important Warnings Drills 1 Remove the chuck key before drill starts 2 High reaction torque can be developed in the case of ...

Page 4: ...le is accidentally engaged LUBRICATION An in line filter regulator lubricator is recommended as it increases tool life and keeps the tool in sustained operation Regularly check and fill the in line lubricator with air tool oil Avoid using excessive amounts of oil Adjust the in line lubricator by placing a sheet of paper next to the tool s exhaust ports and holding the throttle open approximately 3...

Page 5: ... WARNING Disconnect tool from air supply before servicing or changing accessories To install the bits Remove the air supply from the reversible drill Insert the drill bit as far as possible into the opening Using an appropriately sized chuck key turn the chuck key clockwise to securely tighten the drill bit tap or reamer in the drill chuck Always remove the chuck key before connecting the drill to...

Page 6: ...grease There is moisture blowing out of the tool s exhaust There is water in the tank Drain the tank See the air compressor manual for instructions Lubricate the tool and run it until water is not evident Lubricate the tool again and run for 1 2 seconds Warranty Limited Warranty Universal Tool warrants its tools to be free from defects in material and workmanship for one year from the date of purc...

Page 7: ... FLORIDA PNEUMATIC COM Please contact 1 800 356 3392 for further assistance Service Parts Exploded View Drawing ...

Page 8: ...umatic Manufacturing Corporation 851 Jupiter Park Lane Jupiter FL 33458 Universal Tool Questions problems missing parts Call Customer Service 8 a m 5 p m EST Monday Friday 1 800 356 3392 FLORIDA PNEUMATIC COM Retain this manual for future use ...

Reviews: