background image

Universal

 

Walk-In Bathtubs

 

5701 NW 35 Avenue Miami, FL 33142 PHONE: 877-360-4454 FAX: 866-560-1060 www.universaltubs.com

Page 7

OPERATING INSTRUCTIONS

OPERA

TING

  INSTRUCTIONS

Universal

 

Walk-In Bathtubs

 

5701 NW 35 Avenue Miami, FL 33142 PHONE: 877-360-4454 FAX: 866-560-1060 www.universaltubs.com

Page 6

Universal

 

Tubs

tm

Universal

 

Tubs

tm

sa

Fet

Y

saFetY

pre-InstallatIon*

* All Walk-In Bath Tubs are 100% water tested at the factory certified to be free of leaks. Transportation and mishandling may cause leaks. It is necessary to test the bathtub while there is access to 
all sides of the bathtub.

reaD anD FolloW all InstructIons

• 

 Place the tub on a completely flat surface in an area where it may be drained after testing.

• 

Close the drain and fill the tub until it is above the highest jet. If it’s a soaker fill up to normal water height level.

• 

Allow the water to stand in tub for 30 minutes and then inspect all plumbing and seals for leaks. 

• 

If tub is jetted, supply electric to unit and run for 10 minutes and inspect for leaks. Inspect the unions around the pump; if leaks 

persist from the unions after tightening; loosen the unions and insure the O-ring is seated properly. 

note: IF tHe puMps Do not operate, cHecK tHe BreaKer to ensure poWer Is on anD tHe caBle connectIng tHe 

controls to tHe puMp Is attacHeD.

WarnIng!

 Do not run anY puMps unless tHe tuB Is FIlleD WItH Water to proper 

level. DaMage Due to DrY runnIng puMps Is not covereD unDer WarrantY. FaIlure to 

perForM tHese tests BeFore InstallatIon WIll MaKe tHe Installer lIaBle For Future 

repaIr costs.

InstallatIon preparatIon

1.  Check the floor area where the tub is to be installed.

• 

a. Clean area of any debris or trash.

• 

b. Use a 5 or 6-foot level and determine if the floor is level. If the floor is not level, adjust all 5 leveling feet to perfectly level the tub.

• 

note: It Is IMportant tHat all levelIng Feet are coMpletelY toucHIng tHe Floor 
anD level For tHe Door sYsteM to WorK properlY.

2.  Check to ensure that the drain piping has been “roughed-in” at the proper location.

3.  Ensure that the proper electrical service has been installed at the pump location. See electrical requirements in the manual (on 

following page).

Model 30x53

Installation Instructions

 

 

 

P: 

1-866-633-4882 

     www.meditub.com

   

  

  

     

100 East Mineola Avenue, Valley Strem NY 11580

 

   

 

 

MediTub

W h e r e   S a f e t y   M e e t s   L u x u r y

Model 30x53

Installation Instructions

 

 

 

P: 

1-866-633-4882 

     www.meditub.com

   

  

  

     

100 East Mineola Avenue, Valley Strem NY 11580

 

   

 

 

MediTub

W h e r e   S a f e t y   M e e t s   L u x u r y

Summary of Contents for 2653

Page 1: ...iversal Tubs tm Installation operating instructions Installation OPERATING INSTRUCTIONS l30x53 ationInstructions MediTub W h e r e S a f e t y M e e t s L u x u r y 2653 Universal WALK IN BATHTUBS 5701 NW 35 Avenue Miami FL 33142 Phone 877 360 4454 Fax 866 560 1060 info universaltubs com http www universaltubs com MODEL ...

Page 2: ...gistration 3 Savethismanual 4 UNPACKINGTHEUNIT 5 PRE INSTALLATION 6 INSTALLATIONPREPARATION 7 ElectricalPREPARATION 8 INSTALLATIONPROCEDURES 9 DRAINCONNECTION 10 ConnectingtheAutodrain 11 Installationandextensionpanels 12 Faucetinstallation 13 operatingsafetyinstructions 14 operatinginstructions 16 tubcontrols 18 CLEANINGANDMAINTENANCE 19 warranty 20 RETURNPOLICY 22 productregistrationcard 23 Tabl...

Page 3: ...NW 35 Avenue Miami FL 33142 Phone 877 360 4454 Fax 866 560 1060 info universaltubs com http www universaltubs com Thank you contact Product registration Product registration ProductRegistration ToensurethatyourwarrantyisregisteredwithUniversalWalk InBathtubs complete signandreturnthisregistrationcardwithin30daysofthepurchase NOTE Yourwarrantywillnotberecognized by UniversalWalk In Bathtubs unless ...

Page 4: ...AND ELECTRICIANS SHOULD BE EMPLOYED TO INSURE PROPER INSTALLATION INSTALLERS ASSUME ALL LIABILITY FOR THE CORRECT INSTALLATION PROCEDURES ONLY ACCESSORIES AUTHORIZED BY THE MANUFACTURER SHOULDBEUSEDWITHTHISPRODUCT IMPORTANTSAFETYINSTRUCTIONS Warning When USING THIS PRODUCT BASIC PRECAUTIONS SHOULD ALWAYS BE FOLLOWED ReadANDFOLLOWALLINSTRUCTIONSPERTAININGTORISKOFFIRE ELECTRICALSHOCK AND OROTHERINJU...

Page 5: ...dthepump ifleaks persist from theunionsaftertightening loosentheunionsandinsuretheO ringisseatedproperly NOTE Ifthepumpsdonotoperate checkthebreakertoensurepowerisonandthecableconnectingthe controls to the pumpisattached WARNING DO NOT RUN ANY PUMPS UNLESS THE TUB IS FILLED WITH WATER TO PROPER LEVEL DAMAGEDUETODRYRUNNINGPUMPSISNOTCOVEREDUNDERWARRANTY Failureto performthesetestsbeforeinstallationw...

Page 6: ...p GFCI Soaker w Auto Drain w Light 15 Amp GFCI Jet Massage Or Air Massage 15 Amp GFCI Jet Massage Or Air Massage w Light 15 Amp GFCI Jet Massage Or Air Massage w Auto Drain 15 Amp GFCI Jet Massage Or Air Massage w Light Auto Drain 15 Amp GFCI Jet Massage Air Massage Dual 20 Amp GFCI Jet Massage Air Massage Dual w Light 20 Amp GFCI Jet Massage Air Massage Dual w Auto Drain 20 Amp GFCI Jet Massage A...

Page 7: ...theportonthemaindrain Besurethe port is open before attaching the hose Secure the hose with clamps or ties Once the hose is in place close the door on the unit place the handle in the locked posi tion andfilltubwithatleast12 ofwatertotesttheconnection Oncethecompletion of the drain components are installed and have been tested for proper function the unit can be leveled and give a final water test...

Page 8: ...tm extensionpanels assembly placement Connect thetwo panelsusingpre drilledholes Inner flange Top pannel Side pannel Wall Bathroom Waterproof Sheetrock Mortar Tile Silicone Screw 2 piece extension panels Molded flange to bolt unit to wall Custom built wall section s for open ends or install against corners of full wall Faucetinstallation fixing nut fixing nut fixing nut hot control handle cold con...

Page 9: ...ppliances such as a hair dryer lamp telephone radio or television within four feet of thisbathtub Never drop or insertanyobjectsintoanyopenings Do not operatethisunitwithouttheguardoverthesuctionfittings WARNING Riskofhyperthermiaandpossibledrowning Peopleusingmedications herbalremedies sleepaids and orhaving adversemedicalhistoryshouldconsultaphysicianbeforeusingthisproduct WARNING Nofoodoralcoho...

Page 10: ...ontrol button which starts the air flow see page18 Adjustthedirectionandrateofflowofthejetsbymovingthenozzlefordirection Turneithertheoutsideringorthenozzleclockwise orcounterclockwiseforflow somejetsadjusttheflowwiththeoutsideringandsomewiththenozzle Adjusttheairpressureflow ofallwater jetsbyusingtheairvolumecontrol seepage18 whichcontrolsair watermixture Universalwalk intubsequippedwiththechromo...

Page 11: ...romacanister AROMA CANISTER Placed inside the aroma container Check frequently and replaceasneeded 1 2 3 4 6 5 Controlsdepictedmayvaryfromthosefoundonyourunit Varianceisbasedonthe optionspurchasedduringtheorderprocess CLEANING AND MAINTENANCE Pumpandpipecirculationsystemsshouldbeflushedbeforefirstuseandonamonthlybasis when product is undernormal use Belowaretherecommendedproceduresforcleaning Do n...

Page 12: ...r contractor Failure to do so will hereby void the warranty There will be a charge for replacement parts or the replacement of the entire electrical unit if the defective unit is returned for any of the reasons listed above NOTE within the limited one year warranty there will be a prorated charge for any electrical and plated replacementsparts includingshippingandhandlingcharges Manufacturer reser...

Page 13: ...mustbeinitsoriginal packaging and receivedatUniversalWalk InBathtubs insaleablecondition Allreturnswillreceivea15 restockingfeeplusall freight costs of theoriginalshipmentandreturnshipmenttoUniversalWalk InBathtubs Allrequestsfor returnmustfirstbeapprovedbyUniversalWalk InBathtubs andhaveanassignedReturnedMerchandise Authorization number RMA return policy return policy Universal Walk In Bathtubs P...

Page 14: ...lk In Bathtubs 5701 NW 35 Avenue Miami FL 33142 PHONE 877 360 4454 FAX 866 560 1060 www universaltubs com Universal Tubs tm installation OPERATING INSTRUCTIONS installation operating instructions Universal Tubs tm ...

Reviews: