Low Voltage Power Module Installation & Instruction Manual 

ECO SERIES TRANSFORMERS

 

IMPORTANT SAFETY INSTRUCTIONS

 

 

 

WARNINGS:

 

 

 

THIS POWER UNIT MUST BE CONNECTED TO A COVERED GFCI RECEPTACLE MARKED 

“WET

 

LOCATION”

 WHILE IN USE 

 

CAUTION: FOR USE ONLY ON A BRANCH CIRCUIT PROTECTED BY A CLASS A TYPE GROUND 
FAULT CIRCUIT INTERRUPTER 

 

FOR USE WITH LANDSCAPE LIGHTING SYSTEMS ONLY - LANDSCAPE LIGHTING SYSTEMS ARE FOR 
OUTDOOR USE ONLY (NOT FOR USE IN DWELLING UNITS) 

 

THIS DEVICE IS ACCEPTED AS A COMPONENT OF A LANDSCAPE LIGHTING SYSTEM WHERE THE 
SUITABILITY OF THE COMBINATION SHALL BE DETERMINED BY CSA OR LOCAL INSPECTION 
AUTHORITIES HAVING JURISDICTION 

 

DO NOT CONNECT TWO OR MORE POWER SUPPLIES IN PARALLEL 

 

DO NOT MOUNT POWER SUPPLY OR FIXTURES WITHIN 3 METERS (10 FEET) OF A SWIMMING 
POOL OR SPA 

 

DO NOT USE AN EXTENSION CORD WITH THIS POWER SUPPLY 

 

Sizing Transformer

 

 

The total wattage (W) - or volt-amps (VA) for LED - of all of the fixtures operated by this transformer 
must not exceed the wattage rating of the transformer. 

If you are powering halogen lamps

, calculate the load by adding the wattage of the lamps in the system. 

Make sure the load does not exceed the wattage rating of the transformer. 

If you are powering LED lamps or fixtures

, calculate the load by adding the volt/amp (VA) values of all of 

the lamps in the system. VA is calculated using the following formula: 

 

VA =   

Wattage 

Power Factor 

 

 

RISK OF SHOCK.  Install power unit at least 5 feet 
from a pool or spa and at least 10 feet from a 
fountain.  Where the power unit is installed within 
10 feet of a pool or spa, connect unit to a

 

GFCI protected branch circuit.

 

 

 

RISK OF ELECTRIC SHOCK.  Install power 
unit  at least 5 feet from a pool, spa or 
fountain.

 

Where the power unit is installed (a) indoor 
within 10 feet of a pool, spa, or fountain, or

 

(b)  outdoor, connect power unit to a 
receptacle  protected by a GFCI.

 

Summary of Contents for ECO Series

Page 1: ...OT USE AN EXTENSION CORD WITH THIS POWER SUPPLY Sizing Transformer The total wattage W or volt amps VA for LED of all of the fixtures operated by this transformer must not exceed the wattage rating of the transformer If you are powering halogen lamps calculate the load by adding the wattage of the lamps in the system Make sure the load does not exceed the wattage rating of the transformer If you a...

Page 2: ...transformer with a maximum wattage rating of 150W can be utilized MOUNT THETRANSFORMER UNIT 1 Remove transformer door for easy access 2 Find a solid flat surface to mount the transformer in a location a That is at least 12 inches between the terminals and ground level with wire terminals facing down and b Six feet or fewer from a 120V supply circuit that is protected by a Class A type ground fault...

Page 3: ...t exceeds 12V light output of the lamp will be higher but average rated life will be lower If the voltage at the socket is lower than 11V light output will be lower and average rated life will be higher Many LEDs have an input voltage range of 10V 15V or 10V 18V For LEDs with input voltage ranges input voltage supplied to the lamp within that range is acceptable 1 Plug the transformer into a cover...

Page 4: ...Below is a table that lists the cable constant value of different wire gauges Wire Gauge 18 2 16 2 14 2 12 2 10 2 8 2 Cable Constant 1 380 2 200 3 500 7 500 11 920 18 960 Example A 75 ft run with 100W load using 12 2 wire Voltage Drop 75 x 100 x 2 7500 2V This means that a 14V tap is needed to deliver 12V to the final fixture on the run One way to minimize voltage drop in this example is to spread...

Page 5: ...cuit 3 Reset Button Photocell Digital Display Screen Upand Down Arrow Button 4 To Operate Timer a Off No display b On 0 always ON c Auto A On at Dusk Off at Dawn d 1 2 3 4 5 6 7 8 9 On at Dusk Off at 1 2 3 4 5 6 7 8 9 Hrs 1 Timer will stop and reset if unit is exposed to 30sec of light during countdown 2 After full countdown is completed unit will reset only after 1 hours of exposure to lights Not...