26
7.
AFTER SALES SERVICE
Before make use of the after sales Service, please check the
following table:
Fault
Possible Cause
Solution
Light on, but
motor does
not work
Fan switch turned off
Select a fan switch
position
Fan switch failed
Contact service center
Motor failed
Contact service center
Light does
not work,
motor does
not work
House fuses blown
Reset/Replace fuses
Power cord loose or
disconnected
Refit cord to power outlet
Switch power outlet on
Oil leakage
One way valve and the
outlet are not tightly
sealed
Take down the one way
valve and seal with sealant
Leakage from the
connection of chimney
and cover
Take chimney down and
seal
Lights not
working
Broken bulbs
Contact Service center
Insufficient
suction
The distance between the
cooker hood and the gas
top is too far
Refit the cooker hood to
the correct distance
The Cooker
hood
inclines
The fixing screw not tight
enough
Tighten the hanging screw
and make it horizontal