6. ERROR CODE DEFINITIONS

There are two types of error that the keyboard is capable of displaying;
one is where the fault is local to the keyboard and the other is where the
fault is generated from the MV300 Switcher.

6.1. Communication (Local) Error

6.1.1. No Line

This occurs when there are no responses from the switcher.
At this instance, the letters 

‘LinE’

 will appear on the display.

This error may be due to:

i) Incorrect Baud Rate or communication speed with the

switcher.

ii) faulty I.C. (DS3696)

iii) the connecting cable to the switcher is faulty.

6.1.2. Line Error

This occurs when erroneous data are received and the
letters 

‘Lerr’ 

will be displayed on the keyboard display.

The probable causes are:

i) Incorrect Baud Rate or communication speed with the

switcher

ii) faulty I.C. (DS3696)

iii) the connecting cable to the switcher is faulty

6.2. Operation Error

This error is associated with the MV300 Switcher. A qualified
service personnel is required for the repairing.

This fault usually arises during an operation process, whereby the
letter 

‘E’ 

followed by an error number will be displayed. Refer to the

MV300 Switcher manual (Table 1 of Section 3.21) for definitions of
the error numbers.

Summary of Contents for MV950K

Page 1: ...sion Engineering Limited for its use nor for any infringement of patents or other rights of third parties which may result from its use No licence is granted by implication or otherwise under any patent or patent right of UniVision Engineering Limited Operation Manual MV950K KEYBOARD Revision 1 01 October 1996 UniVision Engineering Limited ...

Page 2: ...oning or any form of ventilation Do NOT place the keyboard on unsafe of insecure word surfaces ENSURE that the connecting cable between the MV300 switcher and keyboard is placed in a non obstructive position Do NOT handle the keyboard with unwarranted force or undue care KEEP the keyboard AWAY from liqueous substances CLEAN the outer casing of the keyboard ONLY with a damp clth and mild detergent ...

Page 3: ......

Page 4: ...cher Controls 5 4 1 1 Monitor Selections 5 4 1 2 Camera Selections 5 4 1 3 Camera Movements 5 4 1 4 Lens Motions 5 4 1 5 Run Hold Sequence 5 4 1 6 AUX On 5 4 1 7 AUX Off 5 4 1 8 Pre position Set 5 4 1 9 Pre position Show 5 4 1 10 Global Alarm System On 6 4 1 11 Global Alarm System Off 6 4 1 12 Individual Alarm Enable 6 4 1 13 Individual Alarm Disable 6 4 1 14 Alarm Acknowledge 6 4 1 15 On screen P...

Page 5: ...Operating Temperature 0 to 70 degree Celsius Keyboard connector D9 pin type 1 2 Descriptions Figure 1 shows the front of the keyboard CLOSE 1 2 3 4 5 6 7 8 9 10 CLR ENT SET SHOW ON OFF ALM PGM RUN MON UniVision MV250K IRIS OPEN FOCUS FAR ZOOM TELE WIDE NEAR LED Display Monitor No Camera No Joystick Figure 1 THE OUTLOOK OF THE FRONT OF THE KEYBOARD After being connected to the MV300 Switcher and th...

Page 6: ... 4 5 6 7 8 ϒ ϒ ϒ ϒ ϒ ϒ ϒ ϒ ϒ ϒ ϒ ϒ ϒ ϒ ϒ ϒ ϒ ϒ EXPANDER PORT COM PORT 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 A B A B ALARM INPUT NO COM NC 1 NO COM NC 2 BPA ª BPA BPB BPB BPC BPC BPD BPD Rear Panel of MV300 Switcher KEYBOARD CONNECTORS MV250K Keyboard Figure 2 THE KEYBOARD SETUP PHYSICAL CONNECTION WITH MV300 Upto 4 keyboards can be connected to the MV300 Switcher However note that Keyboard 1 has ...

Page 7: ...key to enable the beeper or depressing the OFF key to disable the beeper To return to normal operation depress the SET key again 2 3 Communication Speed with MV300 The keyboard can communicate with the MV300 switcher at 4 different speeds ie 19200 9600 4800 and 2400bps To see the current speed hold down the SET key until the letter p appears on the monitor number display This is followed by depres...

Page 8: ...s are flashing At this point whenever a key is pressed the key name in abbreviated form will be shown on the camera number display The only exception is the MON key which will display Please refer to Table 2 To return to normal operation depress the PGM key twice Table 2 Key Name Abbreviation IRIS OPEN IRIS CLOSE FOCUS FAR FOCUS NEAR ZOOM TELE ZOOM WIDE SET SHOW ON OFF ALM PGM RUN MON CLR ENT IL I...

Page 9: ...ition 4 1 4 Lens Motions Depress the zoom focus and iris keys to control the lens 4 1 5 Run Hold Sequence Depress the RUN key to toggle between the running and holding sequence The RUN key will light up only when the sequence is running 4 1 6 AUX On Depress the ON key enter the AUX number 1 to 128 and then depress the ENT key 4 1 7 AUX Off Depress the OFF key enter the AUX number 1 to 128 and depr...

Page 10: ...arm number of the selected cameras and depress the OFF key This number can be chosen from 1 to 16 30 46 or 62 dependant on the number of Expander units utilised or 1 to 16 28 44 60 if there are 4 video output instead of 2 4 1 14 Alarm Acknowledge The ALM key will blink if the keyboard has received an alarm acknowledgment request Furthermore once the ALM key is depressed an acknowledgment will be s...

Page 11: ...of the keyboard to the MV300 Switcher is loose of detached Connect the D9 connector of the keyboard to the rear panel of the MV300 properly The keyboard fails to respond correctly or completely The power supply to the keyboard has become non existent of unstable Pull out the D9 connector from the MV300 and then re connect No sound emitted from the alarm beeper Setup power OFF or Beeper is broken r...

Page 12: ... or communication speed with the switcher ii faulty I C DS3696 iii the connecting cable to the switcher is faulty 6 1 2 Line Error This occurs when erroneous data are received and the letters Lerr will be displayed on the keyboard display The probable causes are i Incorrect Baud Rate or communication speed with the switcher ii faulty I C DS3696 iii the connecting cable to the switcher is faulty 6 ...

Page 13: ...is correct at time of publication UniVision Engineering Limited accepts to liability in respect of loss arising from errors in the information provided UniVision Engineering Limited reserves the right to alter specifications without prior notice UniVision Engineering Limited Room 1206 Sunbeam Centre 27 Shing Yip Street Kwun Tong Kowloon Hong Kong Tel 852 2389 3256 Fax 852 2797 8053 ...

Reviews: