125
MISCELLANEOUS MESSAGES
SETUP REQUIRED
It indicates that ECR data might be collapsed because of a low battery condition by battery
discharge while ECR is in stock for a long period.
Perform Physical RAM Test and Auto Preset, then leave ECR ON for minimum of 3 hours
for battery charge.
INITIAL RESET RQ
SYSTEM ERROR : Since Initial Reset is required, perform the initial reset.
IR DONE
INITIAL RESET OPERATION ACCEPTED
--- Pc comm ---
IN PC BATCH COMMUNICATION
PC comm error
PC BATCH COMMUNICATION ERROR
--- PC-IN ---
RECEIVING RAM DATA FROM PERIPHERAL (ECR to ECR RAM data transfer)
--- PC-OUT ---
TRANSFERRING RAM DATA TO PERIPHERAL (ECR to ECR RAM data transfer)
ESF NEAR FULL
displayed on the bottom line
OPTIONAL ESF MEMORY IS NEAR FULL
3371 records out of maximum 3971 if customer bill function is used.
7343 records out of maximum 7943 if customer bill function is not used.
The ESF memory near full condition can be cleared by issuing Z-79 report with data print
by [SF-78.c], by taking Z-8879 by PC (from Tensai2000), or by taking Z-79 report by PC
batch communication.
When ESF memory becomes full, the data first stored, i.e. data at the starting of ESF
memory area, will be deleted from ESF memory (only when [SF-78.b=0] is selected).