30
j) PLU Modifier
By using three modifier keys, this function can be changed from one PLU to three different PLUs. Each
modifier key is given a 3-digit modifier value (left one digit shows value and right two show number of digit).
For example,
modifier value 1 is set at 105,
modifier value 2 is set at 205,
modifier value 3 is set at 305,
Then
MODIFY 1
key places the fifth digit with a value of '1' to the PLU code.
PLU code 1001 is modified to PLU code 11001.
MODIFY 2
key places the fifth digit with a value of '2' to the PLU code.
PLU code 1001 is modified to PLU code 21001.
MODIFY 3
key places the fifth digit with a value of '3' to the PLU code.
PLU code 1001 is modified to PLU code 31001
Bar Coded PLUs:
turn to
X position,
if required
---
PLU
MODIFY
---
scan the PLU
Hard PLUs:
turn to
X position,
if required
---
PLU
MODIFY
---
turn to
R position,
if required
---
HARD
PLU
PLU
Coded PLUs:
turn to
X position,
if required
---
PLU
MODIFY
---
turn to
R position,
if required
--- enter PLU code ---
REPEAT
The following PLU codes are set;
1001:
11001:
21001:
31001:
SODA <S> 0.60
SODA <M> 0.95
SODA <L> 1.25
SODA <LL> 1.50
KEY ENTRY
DISPLAY
RECEIPT
SODA
SODA <S>
0.60
MODIFY 1
-- a
SODA
SODA <M>
, 0.95
SODA <S> 0.60
SODA <M> 0.95
SODA <L> 1.25
SODA <LL> 1.50
MODIFY 2
-- b
SODA
SODA <L>
, 1.25
MODIFY 3
-- c
SODA
SODA <LL>
, 1.50
a: Comma ", " is lit on the above REG lamp.
b: Comma ", " is lit on the above 2nd PRICE lamp.
c: Comma ", " is lit on the above 2nd MENU lamp.
Notes:
-
To exit from the PLU modifier mode, press the same modifier key again.
-
To change the value, press another modifier key.
-
Depending on programming, this modifier value remains for one registration, for one transaction or until the
next
PLU MODIFY
key is pressed.