SECTION I: USER’S INFORMATION

SAFETY

1.

The furnace area must be kept clear and free of combustible mate-
rials, gasoline and other flammable vapors and liquids.

2.

Insulating materials may be combustible. The furnace must be
kept free and clear of insulating materials. The furnace area must
be examined when installed in an attic or other insulated space or
when insulation is added to be sure that the insulation material has
been kept away from the furnace.

3.

The furnace needs air for combustion in order to operate properly
and safely. Do not block or obstruct air openings on the furnace,
air openings to the area where the furnace is installed, or spaces
around the furnace.

4.

Follow the instructions exactly as shown on the OPERATING
INSTRUCTION LABEL or the Start-up and Shutdown Instructions
on Page 3 of this manual when lighting the furnace or turning the
furnace off.

5.

Should the gas supply fail to shut off or if overheating occurs, shut
off the gas valve to the furnace before shutting off the electrical
supply.

6.

Do not use this furnace if any part has been under water. A flood-
damaged furnace is extremely dangerous. Attempts to use the fur-
nace can result in fire or explosion. A qualified service agency
should be contacted to inspect the furnace and replace all gas
controls, control system parts, electrical parts that have been wet
or the furnace if deemed necessary.

FIRE OR EXPLOSION HAZARD - 

Failure to follow

safety warnings exactly could result in serious injury,
death, or property damage.

— Do not store or use gasoline or other flammable

vapors and liquids in the vicinity of this or any
other appliance.

—  WHAT TO DO IF YOU SMELL GAS:

Do not try to light any appliance.

Do not touch any electrical switch; do not use any 
phone (included cell phone) in your building.

Leave the building immediately.

Immediately call your gas supplier from a neighbor’s 
phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire 
department.

—  Installation and service must be performed by a 

qualified installer, service agency or the gas sup-
plier.

CONTACT INFORMATION

Go to website at www.york.com click on “contact”, then click on “contact form” and follow the instructions.

Contact us by mail:

York International

Consumer Relations

5005 York Drive

Norman, OK 73069

TABLE OF CONTENTS

CONTACT INFORMATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1

USER’S INFORMATION  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1

SAFETY   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
INSTRUCTIONS FOR EXAMINING THE 
FURNACE INSTALLATION   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
HOW YOUR GAS FURNACE WORKS   . . . . . . . . . . . . . . . . . . . . . . 3
START-UP AND SHUTDOWN INSTRUCTIONS  . . . . . . . . . . . . . . . 3

Read the Instructions Below Before Trying to Start the Furnace . . 3
Operating Instructions: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
To Turn Off the Appliance: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

FURNACE USER MAINTENANCE . . . . . . . . . . . . . . . . . . . . . . . . . . 4

Air Filters  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Replacing Filters   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Blower Care  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Motor Lubrication  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

SERVICE AND MAINTENANCE MANUAL . . . . . . . . . . . . . . . . . . . . . 5

SAFETY SECTION  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

FURNACE MAINTENANCE SECTION  . . . . . . . . . . . . . . . . . . . . . . .5
FURNACE CLEANING SECTION . . . . . . . . . . . . . . . . . . . . . . . . . . .5

Burner Removal/Cleaning   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Cleaning the Heat Exchanger   . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Cleaning the Secondary Heat Exchanger   . . . . . . . . . . . . . . . . . . .5

SEQUENCE OF OPERATION   . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6

Heating Indoor Fan Off Delay   . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
Continuous Blower:   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
Hot Surface Ignition System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7

TROUBLESHOOTING   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
FURNACE CONTROL DIAGNOSTICS . . . . . . . . . . . . . . . . . . . . . . .7
DIAGNOSTIC FAULT CODE STORAGE AND RETRIEVAL   . . . . . .8

REPLACEMENT PARTS LIST   . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10

REPLACEMENT PART CONTACT INFORMATION   . . . . . . . . . . .12

WIRING DIAGRAM   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
LIMITED WARRANTY  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16

Summary of Contents for GM9T-UP

Page 1: ...at have been wet or the furnace if deemed necessary FIRE OR EXPLOSION HAZARD Failure to follow safety warnings exactly could result in serious injury death or property damage Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any...

Page 2: ...ce casing making sure the physical support is sound without sagging cracks or gaps Examine the furnace base making sure it is physically sound without cracks gaps or sagging and has a good seal 5 Examine the furnace casing for obvious signs of deterioration 6 Examine the burner flames to make sure they are in good adjust ment Refer to the pictorial sketch shown in Figure 2 as a compari son to the ...

Page 3: ...f the control system and any gas control which has been under water Operating Instructions 1 STOP Read the safety information above 2 Set the thermostat to the lowest setting 3 Turn off all electric power to the appliance 4 Remove burner door 5 Move gas control switch to the OFF position Do not force See Figure 4 6 Wait five 5 minutes to clear out any gas If you then smell gas STOP Follow B in the...

Page 4: ... the air filters are on the bottom and the side of the furnace then you have a bottom and side return You must replace both air filters Table 1 will indicate 2 filters by using brackets with the number two 2 D If the air filters are on both sides of the furnace then you have a two sided return You must replace both air filters Table 1 will indicate 2 filters by using brackets with the number two 2...

Page 5: ...ners should be checked periodically for dirt accumulation If cleaning is required follow this procedure 1 Turn off the electrical power to the unit 2 Turn off the gas supply at the external manual shut off valve and loosen the ground union joint 3 Remove the burner door and remove the burner box cover 4 Disconnect wires from flame sensor rollout switch and HSI igniter Remove igniter carefully as i...

Page 6: ...at Low 4 1st Stage Satisfied The Thermostat opens the circuit between R and W1 Immediately the Gas Valve is de energized and Flame Rectifica tion is lost The Inducer Motor is de energized after a 15 second Post Purge and the Hum terminal is de energized The Fan Off Delay circuit is initiated The Delay time can be field set at 60 90 120 or 180 seconds It comes from the fac tory set at 60 seconds Th...

Page 7: ... heat RAPID RED FLASH Twinning error incorrect 24V phasing Check twinning wiring RAPID AMBER FLASH Flame sense current is below 1 5 microamps Check and clean flame sensor Check for proper gas flow 4 AMBER FLASHES The control board is recieving a Y signal from the thermostat without a G signal indicating improper thermostat wir ing 1 RED FLASH This indicates that flame was sensed when there was not...

Page 8: ...a disconnected or loose wire or by a cracked or bro ken igniter STEADY ON RED Control failure Replace control board 60 MINUTE AUTOMATIC RESET FROM LOCKOUT This control includes a watchdog type circuit that will reset from a lockout condition after 60 minutes Operational faults 6 7 8 will be reset This provides protection to an unoccupied structure if a temporary condition exists causing a furnace ...

Page 9: ...NDUCER LOW STAGE PRESSURE SWITCH HSI 1ST STAGE MAIN VALVE FLAME SENSE LOW CIRCULATOR HEAT SPEED 1ST STAGE LOW PRESSURE SWITCH CLOSE RECOGNITION HSI WARM UP 17 SEC IGNITION ACTIVATION PERIOD 4 SEC TRIAL FOR IGNITION 7 SEC INTER PURGE 60 SEC HSI WARM UP 27 SEC IGNITION DEACTIVATION PERIOD 3 SEC HEAT FAN DELAY ON 30 SEC BURN TIME POST PURGE 15 SEC HEAT FAN DELAY OFF SELECTABLE 60 90 120 180 SEC OFF O...

Page 10: ... Products Group SECTION III REPLACEMENT PARTS LIST 25 37 51 26 40 13 61 62 2 60 59 55 7 28 58 16 12 11 24 69 10 39 5 29 31 45 21 46 19 20 48 50 15 53 14 1 3 23 44 2 4 17 42 24 43 22 54 8 34 27 6 29 38 41 37 30 32 9 40 36 47 18 13 ...

Page 11: ...ISCELLANEOUS 37 PLUG WINDOW CLEAR 1 5 38 CONNECTOR AIR INTAKE 2 39 TUBING SILICONE Gray 188 ID 2 ft Req d 40 TUBING PREFORMED 41 GASKET AIR INTAKE 42 GASKET COMBUSTION BLOWER 43 GASKET CONDENSATE PAN 44 GASKET UPPER CONDENSATE PAN 45 GASKET GAS CONTROLS 46 GASKET COND COIL LOWER PAN 2 Req d 47 GROMMET MANIFOLD SEAL 48 GROMMET MOTOR 3 Req d 49 GROMMET 1 2 DIA 50 FERRULE MOTOR MOUNT 3 Req d 51 HANDL...

Page 12: ...ER KIT 1 FILTER 14 1 2 CABINETS 1BR0214 BOTTOM RETURN FILTER KIT 1 4 FILTER 14 1 2 CABINETS 1BR0117 BOTTOM RETURN FILTER KIT 1 FILTER 17 1 2 CABINETS 1BR0217 BOTTOM RETURN FILTER KIT 1 4 FILTER 17 1 2 CABINETS 1BR0121 BOTTOM RETURN FILTER KIT 1 FILTER 21 CABINETS 1BR0221 BOTTOM RETURN FILTER KIT 1 4 FILTER 21 CABINETS 1BR0124 BOTTOM RETURN FILTER KIT 1 FILTER 24 1 2 CABINETS 1BR0224 BOTTOM RETURN ...

Page 13: ...272434 UUM A 0407 Unitary Products Group 13 SECTION IV WIRING DIAGRAM FIGURE 8 Wiring Diagram ...

Page 14: ...272434 UUM A 0407 14 Unitary Products Group NOTES ...

Page 15: ...272434 UUM A 0407 Unitary Products Group 15 NOTES ...

Page 16: ...es only to products installed in the United States and Canada EXCLUSIONS This warranty does not cover any 1 Shipping labor or material charges 2 Damages resulting from transportation installation or servicing 3 Damages resulting from accident abuse fire flood alteration or acts of God tampering altering defacing or removing the product serial number will serve to void this warranty 4 Damages resul...

Reviews: