Never work on the sensors or stove wiring while the
power cord is plugged in.
Doing so may cause a serious shock or damage one of
the electrical components.
WIRE COLOR CODES
Sensor #1 Brown
Draft
Sensor #2 Blue
Trapdoor
Sensor#3
Red
Lid
Sensor#4
Orange
Hopper Overheat
Sensor #5 Black
Fuel
Sensor #6 Yellow
Burnback
Sensor#7
Violet
Thermostat
Combustion Fan
Green
Electro-Magnet
White
White
Heat Exchange Fan
Violet
Auger Motor
Gray
Power Hot
Black
Power Neutral White
utral
White
Power Ground
Green
Gear motor must not exceed 1 rpm rating to prevent