background image

 

11

 

 

 

 

87-94 

blue+yellow 

95-102 

rose red 

103-110 

rose red+fluorescence 

111-119 

fluorwhite 

120-185 

Reverse rainbow, from fast to slow 

186-189 

stop 

190-255 

Positive rainbow, from slow to fast 

16 

13 

 

Fixed disk

 

0-6 

white 

7-13 

gobo1 

14-20 

gobo2 

21-27 

gobo3 

28-34 

gobo4 

35-41 

gobo5 

42-48 

gobo6 

49-55 

gobo7 

56-63 

gobo8 

64-71 

gobo 1 jitter effect,from slow to fast 

72-78 

obo 2 jitter effect,from slow to fast 

79-85 

obo 3 jitter effect,from slow to fast 

86-92 

obo 4 jitter effect,from slow to fast 

93-99 

obo 5 jitter effect,from slow to fast 

100-106 

obo 6 jitter effect,from slow to fast 

107-113 

obo 7 jitter effect,from slow to fast 

114-120 

obo 8 jitter effect,from slow to fast 

121-127 

white

 

128-189 

The dynamic wheel rotates in reverse, 

from fast to slow 

190-193 

stop 

194-255 

The dynamic wheel rotates forward, from 

slow to fast 

17 

14 

 

Rotating 

gobo wheel

 

0-8 

white 

9-17 

gobo1 

18-26 

gobo2 

27-35 

gobo3 

36-44 

gobo4 

45-53 

gobo5 

Summary of Contents for 750 BSWF

Page 1: ...User manual 750 BSWF Please read the instructions carefully before use ...

Page 2: ... 7 DMX Channels 10 14 8 Dimension 15 9 Trouble Shooting 16 10 Fixture Cleaning 16 STATEMENT The product has well capability and intact packing when leave factory All of the user should comply with warning item and manual any misuse cause of the damages are not included in our guarantee and also can not be responsible for any malfunction problem owing to ignore the manual ...

Page 3: ...ure is Ta 40 DO NOT operate it where the temperature is higher than this Unit surface temperature may reach up to 85 DO NOT touch the housing bare hand during its operation Turn off the power and allow about 15 minutes for the unit to cool down before replacing or serving the event of serious operating problem stop using the unit immediately Never try to repair the unit by yourself Repairs carried...

Page 4: ...lute position memory offline power off position recovery Optical system 1 Efficient optical system 2 Strong light output 3 High quality optical lens Moving 1 Pan move angle 540 Accuracy 2 11 Step fine tuning accuracy 0 008 2 Tilt move angle 270 The accuracy is 1 05 Step fine tuning accuracy 0 004 3 pan and tilt magnetic rotary encoder positioning reset system 4 with automatic error correction Dimm...

Page 5: ...in cutting and degree Single light can be turned off completely and the whole module can be rotated 45 Zoom 4 5 50 With automatic adjustment function Heat dissipation It adopts one in one out design cooling fan and dust proof window for heat dissipation Control Standard DMX512 protocol Art net Ethernet control protocol SACN protocol and wireless DMX512 control optional Net weight 29 8Kg Gross weig...

Page 6: ... DOWN buttons to select the submenu press the ENTER button to save the setting or automatically return to the previous menu Press the MENU button to return or wait for 30 seconds to exit the menu mode automatically When there is no power connection press the MENU button for 3 seconds to enter the menu mode After setting press the ENTER button for 1 second or wait for 40 seconds before powering off...

Page 7: ...ection automatic Slave Host Fixture reset Horizontal and vertical Yes No Color Yes No Pattern Yes No Cutting group Yes No Prism focusing Yes No All Yes No Communication options DMX Art DMX ArtNet Wireless Default DMX Network Configuration DHCP IP Address Subnet mask Port settings System message Device version number Motor information Device status Broken record Light source time Equipment running ...

Page 8: ...n The above situation may occur when opening or resetting the machine and some parts may be damaged Please contact an authorized repair center 6 Universal DMX controller control 6 1 Connection 1 In order to reduce signal errors and avoid signal weakening and interference during transmission a 90 120Ω 0 25W resistance can be added between the 2 cores and the 3 cores of the DMX output terminal of th...

Page 9: ...will flash on the display Use the UP and DOWN buttons to select standard mode 53 CH and press the ENTER button to save Press the MENU button to return to the previous menu or wait for 30 seconds to automatically exit the menu mode 6 3 Address code setting When a general DMX controller is used to control the lamp you need to set the starting address 1 512 for the lamp so that the machine can receiv...

Page 10: ...opic from slow to fast 128 191 Gradual stroboscopic from slow to fast 192 251 Random strobe from slow to fast 252 255 Turn on the light 9 8 CMY blue 000 255 Blue CMY From shallow to deep 10 9 CMY rose Red 000 255 Rose red CMY From shallow to deep 11 10 CMY yellow 000 255 Yellow CMY From shallow to deep 12 11 CMY CTO 0 255 CTO From shallow to deep 13 CMY HONG 0 9 No function 10 255 CMY HONG functio...

Page 11: ...fast 72 78 obo 2 jitter effect from slow to fast 79 85 obo 3 jitter effect from slow to fast 86 92 obo 4 jitter effect from slow to fast 93 99 obo 5 jitter effect from slow to fast 100 106 obo 6 jitter effect from slow to fast 107 113 obo 7 jitter effect from slow to fast 114 120 obo 8 jitter effect from slow to fast 121 127 white 128 189 The dynamic wheel rotates in reverse from fast to slow 190 ...

Page 12: ...slow 191 192 Stop 193 255 Reverse rotation from slow to fast 19 Rotation pattern rotation Fine tuning 0 255 16bit adjustable 20 16 Fire plate 0 9 white 10 255 Linear cutting it will rotate when cutting in 21 17 Fire disk rotation 0 124 Forward rotation from fast to slow 125 130 stop 131 255 Reverse rotation from slow to fast 22 18 Prism1 0 14 white 15 255 Prism effect 23 19 Prism 1 rotation 0 127 ...

Page 13: ...ting group 1 motor 1 0 255 0 100 stroke 36 Cutting group 1 motor 1 fine adjustment 0 255 16bit Adjustable 37 29 Cutting group 1 motor 2 0 255 0 100 stroke 38 Cutting group 1 motor 2 fine tuning 0 255 16bit Adjustable 39 30 Cutting group 2 motor 1 0 255 0 100 stroke 40 Cutting group 2 motor 1 fine adjustment 0 255 16bit Adjustable 41 31 Cutting group 2 motor 2 0 255 0 100 stroke 42 Cutting group 2 ...

Page 14: ... 50 Cutting group 4 motor 2 fine adjustment 0 255 16bit Adjustable 51 36 Cutting group rotation 0 255 0 100 stroke 52 Cutting group rotation fine tuning 0 255 16bit Adjustable 53 37 Function channel 0 49 No function 50 149 Self propelled effect 150 209 No function 210 215 XY reset more than 6 seconds 216 219 No function 220 235 Head effect reset after 6 seconds 236 239 No function 240 255 All chan...

Page 15: ...15 8 Dimension ...

Page 16: ...o use another DMX controller 5 Check if the DMX cables run near or run alongside to high voltage cables that may cause damage or interference to DMX interface circuit C One of the channels is not working well 1 The stepper motor might be damaged or the cable connected to the PCB is broken 2 The motor s drive IC on the PCB might be out of condition 10 Fixture Cleaning The cleaning of internal and e...

Reviews: