9
in parallel. DMX512 signal transmission speed is very fast. Damage to the signal line, weak
soldering, poor contact, etc., will affect the signal transmission and cause the system to shut
down
3. When the machine power supply of a certain unit is disconnected, the connection of DMX output
and input is bypassed in order to maintain the connection of the DMX line.
4. Each lamp must have an address code, which can receive the information sent by the console,
the range is between 0-512
(
Usually 0&1 is the same as 1
)
.
5. The terminal of the DMX512 system needs to be equipped with a terminator to reduce signal
transmission errors.
6. 3-pin XLR connector:
3 core XLR
:
PIN 1
:
GND
,
PIN 2
:
Negative signal
,
PIN 3
:
Positive signal
6.2 Channel settings
Press the ENTER button to enter the menu m
ode, select the operating mode → select the channel
mode,
Press the ENTER button to confirm.The current channel mode will flash on the display. Use the UP
and DOWN buttons to select standard mode 53 (CH), and press the ENTER button to save.Press
the MENU button to return to the previous menu or wait for 30 seconds to automatically exit the
menu mode.
6.3 Address code setting
When a general DMX controller is used to control the lamp, you need to set the starting address (1-
512) for the lamp so that the machine can receive the DMX signal.
Press the ENTER button to enter the menu mode, select the DMX function, press the ENTER button
to confirm. The current address will flash on the display, then use the UP/DOWN button to select
the address code (1-512), and press the ENTER button to save.
Please refer to the chart below to set the address codes of the first 4 fixtures:
Channel mode
Lamp 1 address code Lamp 2 address code Lamp 3 address code Lamp 4 address code
53Channel
1
54
107 160
37Channel
1
38
76 114
6.4 DMX 512 channel
Please refer to the following channel diagram to control the lamps.
Note:
1. If the DMX signal is cut off, the lamp will keep the state before the signal is cut off, unless it is
reset.