1 Copyright and disclaimer

Uponor has prepared this installation and operation manual and all
the content included solely for information purposes. The contents of
the manual (including graphics, logos, icons, text, and images) are
copyrighted and protected by worldwide copyright laws and treaty
provisions. You agree to comply with all copyright laws worldwide in
your use of the manual. Modification or use of any of the contents of
the manual for any other purpose is a violation of Uponor’s copyright,
trademark and other proprietary rights.

The presumption for the manual is that the safety measures have
been fully complied with and that the Port system as covered by the
manual (including any components ):

is selected, planned and installed and put into operation by a
licensed and competent planner and installer in compliance with
current (at the time of installation) installation instructions
provided by Uponor as well as in compliance with all applicable
building and plumbing codes and other requirements and
guidelines;

has not been (temporarily or continuously) exposed to
temperatures, pressure and/or voltages that exceed the limits
printed on the products or stated in any instructions supplied by
Uponor;

remain in its originally installed location and is not repaired,
replaced or interfered with, without prior written consent of
Uponor;

is connected to potable water supplies or compatible plumbing,
heating and/or cooling products approved or specified by
Uponor;

is not connected to or used with non-Uponor products, parts or
components except for those approved or specified by Uponor;
and

does not show evidence of tampering, mishandling, insufficient
maintenance, improper storage, neglect or accidental damage
before installation and being put into operation.

While Uponor has made efforts to ensure that the manual is accurate,
Uponor does not guarantee or warrant the accuracy of the
information contained herein. Uponor reserves the right to modify the
specifications and features described herein, or discontinue
manufacture of the Uponor products described at any time without
prior notice or obligation. The manual is provided “as is” without
warranties of any kind, either expressed or implied. The information
should be independently verified before using it in any manner.

To the fullest extent permissible, Uponor disclaims all
warranties, expressed or implied, including, but not limited to,
the implied warranties of merchantability, fitness for particular
purpose and non-infringement.

This disclaimer applies to, but is not limited to, the accuracy, reliability
or correctness of the manual.

Under no circumstances shall Uponor be liable for any indirect,
special, incidental or consequential damages or loss that result
from the use of or the inability to use the materials or
information in the manual, or any claim attributable to errors,
omission or other inaccuracies in the manual, even if Uponor
has been advised of the possibility of such damages.

This disclaimer and any provisions in the manual do not limit
any statutory rights of consumers.

Combi Port XS

  |  

Installation and operation manual

  | 

3

Summary of Contents for Combi Port XS

Page 1: ...Combi Port XS EN Installation and operation manual SD0000126...

Page 2: ...shing 9 5 5 Tightness testing 10 5 6 Commissioning and hand over 10 6 Operation 11 6 1 Cold water throttle disc 11 6 2 Strainer 11 6 3 Thermostatic temperature lead module TTV 11 6 4 Circulation pump...

Page 3: ...pecified by Uponor is not connected to or used with non Uponor products parts or components except for those approved or specified by Uponor and does not show evidence of tampering mishandling insuffi...

Page 4: ...flammable vapours or gases Uponor cannot accept any responsibility for damage or breakdown that can result from ignoring these instructions 2 2 Standards and regulations Note The installation must be...

Page 5: ...for details of where and how they can take this item for environmentally safe recycling Business users should contact their supplier and check the terms and conditions of the purchase contract This p...

Page 6: ...alve is controlling the process As more hot water is required as more the valve is opening the flow of the heating water through the heat exchanger This ensures a constant hot water temperature If no...

Page 7: ...essure regulator optional L Zone valve for limiting heating flow to apartment M Sensor pocket heat meter N Heat meter distance piece O Strainer 3 4 Accessories Depending on customer requirement the ba...

Page 8: ...ort or installation Check the nuts to ensure that they are properly tightened before the connection to avoid property damages Before installing the heat interface unit ensure that the primary pipes ar...

Page 9: ...entation SD0000106 Connect the primary supply lines with the corresponding ball valves at the HIU 5 3 Electrical installation Warning Required electrical connections and installations commissioning an...

Page 10: ...iately Minimum 2 hours According to local standards and regulations 5 6 Commissioning and hand over Caution Improper commissioning can lead to property damage Complete commissioning by following these...

Page 11: ...e capillary pipe 6 mm Note A too high value can cause the heating water return temperature to rise Note A too low maintenance temperature setting can lead to longer waiting times when preparing domest...

Page 12: ...70 C 35 40 45 50 55 60 65 70 Change default settings Caution Make sure not to bend or break the capillary line SI0000286 2 3 4 The thermostat is equipped with a pin that limits the temperature to 60 C...

Page 13: ...for assembly in the line and protects other control valves such as the proportional volume control from the excessive differential pressure that otherwise could cause the fitting to overflow Descript...

Page 14: ...are filled and pressurised The cold water supply for the apartment is provided via the central house connection and distribution line The heat interface unit is equipped with a central shut off ball v...

Page 15: ...iter infinitely adjustable downwards 35 70 C limited to 60 C 6 Scale value 35 70 C 1 2 3 4 5 6 7 8 Hot water temperature 35 C 40 C 45 C 50 C 55 C 60 C 65 C 70 C TTV Thermostatic lead module TTV capill...

Page 16: ...rmostatic hot water temperature limiter if installed is working and correctly set Proportional volume control does not switch over Replace the proportional volume controller Waiting time for hot water...

Page 17: ...rically Radiator thermostatic valves or return screw connections closed Check the thermostatic valves and return screw connections on the radiators No hot water and no heating Ball valves closed Open...

Page 18: ...495 mm 200 mm 501 mm 350 mm 198 mm Connection measurents w l l1 l2 l3 l4 l5 h1 ZD0000062 w2 w1 w3 h l l1 l2 l3 l4 l5 495 mm 303 mm 60 mm 94 mm 93 mm 95 mm w w1 w2 w3 h h1 501 mm 361 mm 401 mm 406 mm...

Page 19: ...tial pressure regulator M Cold water meter distance piece N Heat meter distance piece O Sensor pocket heat meter P Strainer Q Swivel nut R Ball valve 9 3 Technical specifications Combi Port XS Value M...

Page 20: ...differential pressure regulator kvs 1 46 H HIU without strainer kvs 1 70 Pressure losses including ball valve Additional pressure losses e g heatmeter with Qn 1 5 of approximately 0 05 bar and other...

Page 21: ...ture C X Primary heating supply temperatures Y Tapping capacity in litres minute l min Z Max range Cold water warming 40 K 10 50 C 55 50 45 40 35 30 25 20 15 10 5 10 15 20 25 W Y 1200 1100 1000 900 80...

Page 22: ...ng supply temperatures Y Tapping capacity in litres minute l min Z Max range Cold water warming 50 K 10 60 C 55 50 45 40 35 30 25 20 15 10 5 10 15 20 25 W X 1200 1100 1000 900 800 700 600 500 400 300...

Page 23: ...al pressure regulator kvs 1 46 H HIU without strainer kvs 1 70 Pressure losses including ball valve Additional pressure losses e g heatmeter with Qn 1 5 of approximately 0 05 bar and other internal ex...

Page 24: ...ture C X Primary heating supply temperatures Y Tapping capacity in litres minute l min Z Max range Cold water warming 40 K 10 50 C 40 35 30 25 20 15 10 5 0 5 10 15 20 25 W Y 1200 1100 1000 900 800 700...

Page 25: ...ng supply temperatures Y Tapping capacity in litres minute l min Z Max range Cold water warming 50 K 10 60 C 40 35 30 25 20 15 10 5 0 5 10 15 20 25 W Y 1200 1100 1000 900 800 700 600 500 400 300 200 1...

Page 26: ...al pressure regulator kvs 1 46 H HIU without strainer kvs 1 70 Pressure losses including ball valve Additional pressure losses e g heatmeter with Qn 1 5 of approximately 0 05 bar and other internal ex...

Page 27: ...X Primary heating supply temperatures Y Tapping capacity in litres minute l min Z Max range Cold water warming 40 K 10 50 C 40 35 30 25 20 15 10 5 0 5 10 15 20 25 W Y 1200 1100 1000 900 800 700 600 5...

Page 28: ...ng supply temperatures Y Tapping capacity in litres minute l min Z Max range Cold water warming 50 K 10 60 C 40 35 30 25 20 15 10 5 0 5 10 15 20 25 W Y 1200 1100 1000 900 800 700 600 500 400 300 200 1...

Page 29: ...ermany 1120090 v1_04_2021_EN Production Uponor DCO Uponor reserves the right to make changes without prior notification to the specification of incorporated components in line with its policy of conti...