4 CONNECTING STEPS TO USE UE-12Li100BL IN SERIES
Connecting Steps:
3 Connect the batteries according to the pictures below with the finished wires in step 2, and make
sure the anode that comes out from
PACK4
is on the positive pole, while the cathode that comes
out from
PACK1
is on the negative pole.
2
a
: Weld OT connectors and wires tightly.
b
: Cover the connecting part, between OT connectors and wires, with the Heat Shrink Tube.
a
b
1 Preparation Material
OT connector
10PCS
(Bare >100A current)
Heat Shrink Tube
10PCS
(4cm/PC)
Wires (Bare > 100A,
Length depends on
customer)
UE-12Li100BL
4PCS
(Voltage difference < 0.2V)
INSTALLATION MANUAL