Chapter 3 – Safety
SB47JRT – 0075522
11
It is best not to transfer from the platform to another struc-
ture or from the structure to the platform, unless that is
the safest way to do the job. Judge each situation sepa-
rately taking the work environment into account. If it is
necessary to transfer from the platform to another struc-
ture the following guidelines apply:
1. Where possible, place the platform over a roof or
walking structure to do the transfer.
2. Transfer your anchorage from one structure to the
other before stepping across.
3. Remember that you might be transferring to a struc-
ture where
personal fall arrest
is required.
4. Use the platform entrance, do not climb over or
through the guardrails.
Do not operate the aerial platform in windy or gusty con-
ditions. Do not add anything to the aerial platform that
will increase the wind loading such as billboards, ban-
ners, flags, etc.
Never operate the aerial platform without all parts of the
guardrail system in place and the gate closed. Make sure
that all protective guards, cowlings, and doors are se-
curely fastened.
Do not exceed the platform capacity as indicated on the
platform rating placard on the platform. Do not carry loads
that extend beyond the platform guardrails without prior
written consent from UpRight.
Do not operate the aerial platform from trucks, trailers,
railway cars, floating vessels, scaffolds, or similar equip-
ment unless the application is approved in writing by
UpRight.
Do not use the aerial platform as a crane, hoist, jack, or
for any purpose other than to position personnel, tools,
and materials.
Do not climb on the guardrails or use ladders, planks, or
other devices to extend or increase the work position
from the platform.
Take care to prevent rope, electrical cords, and hoses,
etc., from becoming caught in or on the aerial platform. If
the platform or booms becomes caught on an adjacent
structure or other obstacle and is prevented from normal
motion, reverse the control to free the platform. If control
reversal does not free the platform, evacuate the platform
before attempting to free it.
Electrical System
Charge the batteries in a well-ventilated area free of flame,
sparks, or other hazards that might cause fire or explo-
sion.
Do not operate any of the aerial platform functions while
the battery charger is plugged in.
A
Warning
Batteries give off hydrogen and oxygen that can
combine explosively. Death or serious injury could
result from a chemical explosion. Do not smoke or
permit open flames or sparks when checking the
batteries.
Battery acid can damage the skin and eyes. Seri-
ous infection or reaction can result if medical treat-
ment is not given immediately. Wear face and eye
protection when working near the batteries.
Batteries contain sulfuric acid that can damage your eyes
or skin on contact. Wear a face shield, rubber gloves,
and protective clothing when working around batteries. If
acid contacts your eyes, flush immediately with clear
water and get medical attention. If acid contacts your
skin, wash off immediately with clear water.
Hydraulic System
The hydraulic system contains hoses with hydraulic fluid
under pressure.
A
Danger
Hydraulic fluid escaping under pressure can have
enough force to inject fluid into the flesh. Serious
infection or reaction will result if medical treatment
is not given immediately. In case of injury by escap-
ing hydraulic fluid, seek medical attention at once.
Do not place your hand or any part of your body in front of
escaping hydraulic fluid. Use a piece of cardboard or wood
to search for hydraulic leaks.
Engine and Fuel Handling Precautions
Refer to the engine manufacturer’s Operator’s Manual for
complete information on safe engine operation, mainte-
nance, and specifications.
A
Danger
Engine exhaust contains carbon monoxide, a poi-
sonous gas that is invisible and odorless. Breathing
engine exhaust fumes will cause death or serious
illness. Do not run the engine in an enclosed area
or indoors without adequate ventilation.
Be careful not to run the diesel fuel tank empty. Bleed
the fuel system if air enters the lines between the tank
and the injection pump.
Allow the engine to return to idle before shutting the en-
gine off.
Do not smoke or permit open flames while fueling or near
fueling operations.
Summary of Contents for SB47JRT
Page 1: ...SB47JRT Operator Manual Jan 08 PN 508361 000 SB47JRT ...
Page 2: ......
Page 6: ......
Page 13: ...Chapter 2 Specifications SB47JRT 0075522 7 Engine Oil Viscosity Cummins B3 3 Deutz F3L 2011F ...
Page 14: ...Chapter 2 Specifications 8 SB47JRT 0075522 ...
Page 30: ...Chapter 6 Controls 24 SB47JRT 0075522 ...
Page 44: ...Chapter 7 Prestart Inspection 38 SB47JRT 0075522 ...
Page 50: ...Chapter 8 Operation 44 SB47JRT 0075522 Figure 8 6 Platform Work Lights ...
Page 58: ...Chapter 10 Emergency Operation 52 SB47JRT 0075522 ...
Page 64: ...Chapter 11 Troubleshooting 58 SB47JRT 0075522 ...
Page 66: ...Appendix A Glossary SB47JRT 0075522 ...
Page 67: ......