Page 3-26
Maintenance
3.14 - Tilt Sensor
TM12 Work Platform - European
3.14 T
ILT
S
ENSOR
The Tilt Sensor has three wires; red-power (24v in), black-ground, white-output (24v out). To ver-
ify the sensor is working properly, there is one red LED under the sensor. If the LED is on, the
sensor is off level..
Figure 3-23:
Tilt Sensor
A
DJUSTMENT
1. Place machine on firm level sur-
face ±¼°.
2. Use the Inclinometer
(p/n 010119-000) to ensure front
and rear of Chassis is level ±¼°.
3. Adjust the three leveling screws
until the bubble is centered in
the circle on the attached bubble
level.
T
EST
1. Raise the platform approxi-
mately 7 feet (2 meters).
2. Support the elevating assembly
(see “3.7 Supporting Elevating
Assembly” on Page 3-6).
3. Push the level sensor to the side.
The red LED should turn on, and the tilt alarm should sound.
W A R N I N G
!
!
Never perform service on the work platform in the elevating assembly area
while platform is elevated without first blocking the elevating assembly.
DO NOT stand in elevating assembly area while deploying or storing brace.
Adjusting Screws
(only one visible)
Bubble Level
Summary of Contents for TM12
Page 1: ...TM12 ...
Page 10: ...Page VI Table of Contents List of Tables TM12 Work Platform European NOTES ...
Page 60: ...Page 3 34 Maintenance 3 18 Torque Specifications TM12 Work Platform European NOTES ...
Page 74: ...Page 5 6 Schematics 5 3 Hydraulic Tm12 Work Platform European NOTES ...
Page 79: ...Page 6 5 Illustrated Parts Breakdown TM12 Work Platform European NOTES ...
Page 81: ...Page 6 7 Illustrated Parts Breakdown Basic Assembly TM12 Work Platform European ...
Page 88: ...Page 6 14 Illustrated Parts Breakdown Hose Kit TM12 Work Platform European ...
Page 101: ......