APP-B Technical Specifications 

Model 

425A/AP 

525A/AP 

625A/AP 

825A/AP 

1000A/AP 

Configuration 

Capacity (VA) 

425 VA 

525 VA 

625 VA 

825 VA 

1000 VA 

Capacity (Watts) 

255 W 

315 W 

375 W 

495 W 

550 W 

Form 

Tower Type 

Input 

Voltage 

100 / 110 / 120 VAC or 220 / 230 / 240 VAC 

Input Voltage Range 

75 - 150 or 165 - 300 VAC 

Input Frequency Range 

50 Hz / 60 Hz (Auto Sensing) 

Output 

Waveform

(Battery-Mode)

 

Simulated Sine Wave 

Voltage 

100 / 110 / 120 VAC or 220 / 230/ 240 VAC 

Frequency

(Battery-Mode)

 

50 Hz / 60 Hz ± 0.5 Hz   

Transfer Time 

2 - 4 ms (Typical) 

Protection 

Full Protection 

Overload, Surge, Short Circuit 

Tele Communication 

RJ11 / RJ45 : AP model 

Battery 

Type 

12V 7.2Ah 

12V 9 Ah 

Quantity 

Typical Recharge Time 

6-8 hr to 90% 

Management & Communication 

Indicator 

LED Control Panel : IMP model 

Digital Control Panel : IMD model 

Communication Port 

USB B type : AP model 

Physical 

Dimensions (WxDxH) (mm) 

105 x 334 x 168 

Weight (kgs) 

6.1 

6.1 

6.3 

6.8 

6.8 

Shipping Dimensions (mm) 

196 x 410 x 263 

Shipping Weight (kgs) 

7.4 

7.4 

7.6 

8.1 

8.1 

Alarm 

Overload / Fault 

Continuous Beeping 

Battery Mode 

Beep every 2 seconds 

Low Battery 

Beep every 0.5 second 

Environment 

Operating Humidity 

  0-90 % RH at 0-40°C (Non-condensing) 

Audible Noise 

Less than 40 dB 

 

* Specifications are subject to change without further notice. 

* Specifications are for reference; actual information should be based on the real product.

 

Summary of Contents for 1000A/AP

Page 1: ...U P S Line Interactive 425VA 1000VA USER MANUAL ...

Page 2: ...ations If by turning on and off you conclude that the equipment s harmful interference influences your radio or television reception use one of the following preventive measures Place the receiving antenna in a separate location or orientation Ensure a greater distance between the receiver and the equipment Ensure that your Equipment connects to an outlet on a separate circuit Contact a technician...

Page 3: ... panel view 4 3 2 Connection to Main and Load 4 4 Operation 5 4 1 General Description 5 4 2 System Configuration 5 4 3 Panel overview 5 4 4 UPS Control 6 4 5 UPS Configuration 7 5 UPS Monitoring Connection 7 6 Maintenance 8 6 1 Transportation 8 6 2 Storage 8 6 3 Operation 8 6 4 Battery 8 6 4 1 Maintenance 8 6 4 2 Replacement 8 APP A Troubleshooting 9 APP B Technical Specifications 10 ...

Page 4: ...ects from the main power since residual voltage exists due to battery supply CAUTION Beware of all the details on the cautionary sticker located on UPS CAUTION No user serviceable parts Do not attempt to remove the unit s cover no user serviceable parts inside Please refer all service to qualified service technicians CAUTION DO NOT dispose UPS and its batteries to fire the battery may explode CAUT...

Page 5: ...zardous situations to personnel and equipment Ensure the main power voltage matches with UPS 110V 220V For electrical installation closely observe the nominal current rating of the source Check the equipment s power requirement to prevent overloading situations Do not connect devices that draw either massive power shortly or half wave rectified current such as hairdryer vacuum cleaner laser printe...

Page 6: ...y while connected to power During a power failure the UPS will switch to Battery Mode in which power is maintained from the battery In case of failure time exceed Battery Mode duration UPS will shut down until voltage return to prevent battery discharge Diagnostic Test While the advanced battery management system monitors the conditions of the batteries it sends early warnings if a battery replace...

Page 7: ...icates the UPS is over loaded OVER LOAD indicator Red The indicator illuminates when the connected loads exceed the maximum rated capacity Battery level bar It indicates the battery capacity and battery status When the battery capacity is low it becomes dim when the battery needs to be replaced or the charger of UPS is fail to function indicators on all the bar flash Output Voltage This digital in...

Page 8: ...can also be enabled or disabled via monitoring software Green Mode Enable Turn on UPS normally Green mode activates in default Green Mode Disable When turning on UPS please keep holding the ON button until a double beep occurred 4 5 UPS Configuration UPS Manual test Manual tests for UPS or battery can be conducted from the UPS configuration as well and are functional even when the UPS is not charg...

Page 9: ...g to safety instruction otherwise the safety of installation personnel cannot be guaranteed since the unit may malfunction Please ensure no flammable substances such as gases or fumes Avoid extreme temperature and humidity Protect the equipment from moisture Ensure there is enough space 300mm or above recommended at the rear and side of UPS for proper ventilation Ensure that the front of the UPS r...

Page 10: ...low battery power Check the main power connection If operating with battery power ensure enough charging time for UPS Time of pressing the button is too short Press and hold the ON button for a longer duration Output short circuit or overload on UPS Turn off UPS and take off all load Check for any potential internal short circuit Then attempt to turn on UPS again Hardware failure Contact for techn...

Page 11: ... Protection Overload Surge Short Circuit Tele Communication RJ11 RJ45 AP model Battery Type 12V 7 2Ah 12V 9 Ah Quantity 1 1 Typical Recharge Time 6 8 hr to 90 Management Communication Indicator LED Control Panel IMP model Digital Control Panel IMD model Communication Port USB B type AP model Physical Dimensions WxDxH mm 105 x 334 x 168 Weight kgs 6 1 6 1 6 3 6 8 6 8 Shipping Dimensions mm 196 x 41...

Reviews: