Button operation 

Cold Start function 

When  the  main  power  is  disconnected  from  UPS,  it  is  capable  of  starting  with 

battery power for users’ needs. Simply start the UPS as the instruction below. 

  “On/Off/Test/Silence” button 

Turn on the UPS 

 

Switch on the Load 

 

Press the "ON" button until a single "beep" alarm disappeared or the LED display 

turns on. 

Shut Down the UPS

 

 

Switch off the Load 

 

Press the "OFF" button for 3 seconds during Line/Battery-mode. 

 

(If  applicable)  To  avoid  electrical  hazards,  please  turn  off  the  internal/external 

input  breaker.  Then,  turn  off  any  external  battery  breaker  and  wait  till  all  fans 

completely shut down. 

Test 

Press once to start self-test function during Line-Mode 

Silence 

Press once to enable/disable alarm buzzer during Battery-Mode 

Green mode 

The  Green  mode  feature  will  enable  UPS  no-Load  or  light-load  shutdown  to 

maintain power consumption and battery life. During battery mode, the UPS will shut 

down approximately 4 min with no load/light load operating. 

Green mode can also be enabled or disabled via monitoring software. 

Green Mode Enable: Turn on UPS normally. Green mode activates in default.

 

Green Mode Disable: When turning on UPS, please keep holding the “ON” button until 

a double “beep” occurred.

 

4.5 UPS Configuration 

UPS Manual test 

Manual tests for UPS or battery can be conducted from the UPS configuration as 

well and are functional even when the UPS is not charging the battery. 

Simple test

: It’s recommended to conduct a simple simulation test when. 

1. The first use of UPS. 

2. Adding new loads. 

3. 6 months’ regular check-up 

Switch on the UPS and wait for the power indicator to light up, then unplug UPS to 

simulate the main power failure. 

Manual Battery Test: Press the “test” button once. UPS will automatically conduct 

a self-test. Please note that the UPS will briefly switch to battery mode. 

5.

 

UPS Monitoring Connection 

 

UPSMON Pro software (Or other power monitoring  software) can further utilize 

the  UPS  with  warning  reminders,  monitoring,  control  shut  down,  and  setting 

adjustments. 

Using monitoring features requires connecting the UPS to a computer or the internet. 

Connect UPS to Computer with USB (Optional)

 

 

Locate the USB port on UPS. 

 

Connect with factory-provided. 

 

Ensure your computer can install and support power management software. 

Summary of Contents for 1000A/AP

Page 1: ...U P S Line Interactive 425VA 1000VA USER MANUAL ...

Page 2: ...ations If by turning on and off you conclude that the equipment s harmful interference influences your radio or television reception use one of the following preventive measures Place the receiving antenna in a separate location or orientation Ensure a greater distance between the receiver and the equipment Ensure that your Equipment connects to an outlet on a separate circuit Contact a technician...

Page 3: ... panel view 4 3 2 Connection to Main and Load 4 4 Operation 5 4 1 General Description 5 4 2 System Configuration 5 4 3 Panel overview 5 4 4 UPS Control 6 4 5 UPS Configuration 7 5 UPS Monitoring Connection 7 6 Maintenance 8 6 1 Transportation 8 6 2 Storage 8 6 3 Operation 8 6 4 Battery 8 6 4 1 Maintenance 8 6 4 2 Replacement 8 APP A Troubleshooting 9 APP B Technical Specifications 10 ...

Page 4: ...ects from the main power since residual voltage exists due to battery supply CAUTION Beware of all the details on the cautionary sticker located on UPS CAUTION No user serviceable parts Do not attempt to remove the unit s cover no user serviceable parts inside Please refer all service to qualified service technicians CAUTION DO NOT dispose UPS and its batteries to fire the battery may explode CAUT...

Page 5: ...zardous situations to personnel and equipment Ensure the main power voltage matches with UPS 110V 220V For electrical installation closely observe the nominal current rating of the source Check the equipment s power requirement to prevent overloading situations Do not connect devices that draw either massive power shortly or half wave rectified current such as hairdryer vacuum cleaner laser printe...

Page 6: ...y while connected to power During a power failure the UPS will switch to Battery Mode in which power is maintained from the battery In case of failure time exceed Battery Mode duration UPS will shut down until voltage return to prevent battery discharge Diagnostic Test While the advanced battery management system monitors the conditions of the batteries it sends early warnings if a battery replace...

Page 7: ...icates the UPS is over loaded OVER LOAD indicator Red The indicator illuminates when the connected loads exceed the maximum rated capacity Battery level bar It indicates the battery capacity and battery status When the battery capacity is low it becomes dim when the battery needs to be replaced or the charger of UPS is fail to function indicators on all the bar flash Output Voltage This digital in...

Page 8: ...can also be enabled or disabled via monitoring software Green Mode Enable Turn on UPS normally Green mode activates in default Green Mode Disable When turning on UPS please keep holding the ON button until a double beep occurred 4 5 UPS Configuration UPS Manual test Manual tests for UPS or battery can be conducted from the UPS configuration as well and are functional even when the UPS is not charg...

Page 9: ...g to safety instruction otherwise the safety of installation personnel cannot be guaranteed since the unit may malfunction Please ensure no flammable substances such as gases or fumes Avoid extreme temperature and humidity Protect the equipment from moisture Ensure there is enough space 300mm or above recommended at the rear and side of UPS for proper ventilation Ensure that the front of the UPS r...

Page 10: ...low battery power Check the main power connection If operating with battery power ensure enough charging time for UPS Time of pressing the button is too short Press and hold the ON button for a longer duration Output short circuit or overload on UPS Turn off UPS and take off all load Check for any potential internal short circuit Then attempt to turn on UPS again Hardware failure Contact for techn...

Page 11: ... Protection Overload Surge Short Circuit Tele Communication RJ11 RJ45 AP model Battery Type 12V 7 2Ah 12V 9 Ah Quantity 1 1 Typical Recharge Time 6 8 hr to 90 Management Communication Indicator LED Control Panel IMP model Digital Control Panel IMD model Communication Port USB B type AP model Physical Dimensions WxDxH mm 105 x 334 x 168 Weight kgs 6 1 6 1 6 3 6 8 6 8 Shipping Dimensions mm 196 x 41...

Reviews: