background image

HotLok

®

 Switchfix 

Part Numbers 

SF001-PR3  

Installation Guide

Each carton contains:

Switchfix adjustable chassis (1), Channel Arms (2), 10x32 Screws (6), Installation Guide (1)

Tools and Preparation Required for Installation

Tools Required:

Phillips Screwdriver

Hardware Required:

10x32 Cage Nuts (4-8), 10x32 Screws (4-8)

Specifications

Part Number

Description

Dimensions

Quantity per 

Carton

Shipping

Weight

SF001-PR3

Passive, Switch Rear Intake, 

1U, Adjustable, Black

10

”-14.63” (254mm - 372mm)

1

21 lbs.

REAR/HOT AISLE

FRONT/COLD AISLE

Installation Precaution 

•  Ensure the SwitchFix is installed 

so that it does not limit the airflow 
required for the safe operation of 
the equipment. 

•  Do not interfere with the switch 

power cords when installing on a 
live unit. 

•  Take necessary precautions when 

handling electrical components.  

Summary of Contents for HOTLOK Switchfix SF001-PR3

Page 1: ...ws 4 8 Specifications Part Number Description Dimensions Quantity per Carton Shipping Weight SF001 PR3 Passive Switch Rear Intake 1U Adjustable Black 10 14 63 254mm 372mm 1 21 lbs REAR HOT AISLE FRONT COLD AISLE Installation Precaution Ensure the SwitchFix is installed so that it does not limit the airflow required for the safe operation of the equipment Do not interfere with the switch power cord...

Page 2: ...itchFix inserted into channels The SwitchFix does not ship in the fully extended position from the factory Extend the SwitchFix by pulling evenly on the mounting rail tabs to the deepest depth 4 Prior to installing the SwitchFix attach the switch power cords to the power supply handle located towards the center of the switch The switch power cords can be passed through the SwitchFix brush strip al...

Page 3: ...re to follow computer manufacturer s guidelines for maintaining proper cooling may result in the overheating of equipment Before installing the SwitchFix ensure that there is adequate airflow to the intake side of the computer equipment or cabinets through devices such as perforated floor tiles or grates Delivering proper airflow to the intake side of computer equipment and or cabinets is the resp...

Page 4: ...o the Company or its manufacturer and 2 The product must not have been abused misused or improperly maintained and or non Upsite authorized repair performed during such period and 3 Such defect has not been caused by corrosion or exposure to other than ordinary wear and tear and 4 The installation and use of the product has been in accordance with the manufacturer s instructions and not been modif...

Reviews: