background image

Figure 1

STEP 2

-

Attach Crossbar to Outlet Box

A. Attach the Crossbar (A) to Outlet Box and secure by

threading Outlet Box Screws (not supplied) into the
Mounting Holes on the Outlet Box. Tighten until snug.

Crossbar

Outlet
Box

Outlet Box
Screw

Mounting

Hole

Figure 2

3of5

Crossbar

Mounting Screw

Lock Washer

Hex Nut

Fixture

Body

STEP 1

-

Attach Mounting Screws, Lock

Washers and Hex Nuts to Crossbar

A. Line up a set of holes on the Crossbar (A) and Holes on

the backplate of the Fixture Body (F).

B. Thread Mounting Screws (B) into the holes on the

Crossbar (A), pass Lock Washers (C) and thread Hex
Nut (D) onto the Mounting Screws (B). Hand tighten
until snug.

SKU: UQL1170

www.urbanambiance.com

Summary of Contents for Manchester UQL1170

Page 1: ...Make sure bulbs are given sufficient time to cool before removal Do not subject glass parts to any shock while in operation or shattering may result A B C D F E Mounting Ball Mounting Screw 1of5 Tools Required Flathead screwdriver Phillips screwdriver pliers wire cutters wire strippers electrical tape safety glasses EstimatedAssembly Time 20 30 minutes Bulb Recommended 1 Medium Base 100W Maximum P...

Page 2: ...UQL1170 1 2 PART NUMBER UQL1170KIT 1 100W medium base bulbs not Supplied NOTE ALL DIMENSIONS ARE ROUNDED UP TO THE NEAREST 1 2 REPLACEMENT PART DESCRIPTION MTG HDW 4 D REQ 1 NO 3 2of5 5 5 3 5 4 5 6 7 5 17 1 ...

Page 3: ...rew Mounting Hole Figure 2 3of5 Crossbar Mounting Screw Lock Washer Hex Nut Fixture Body STEP 1 Attach Mounting Screws Lock Washers and Hex Nuts to Crossbar A Line up a set of holes on the Crossbar A and Holes on the backplate of the Fixture Body F B Thread Mounting Screws B into the holes on the Crossbar A pass Lock Washers C and thread Hex Nut D onto the Mounting Screws B Hand tighten until snug...

Page 4: ...supplied with connectors B Connect White Supply Wire from the Outlet Box to White Wire from fixture C Connect Black or Red Supply Wire from the Outlet Box to Black Wire from fixture D Connect Ground Wire from the Outlet Box to Ground Wire from fixture E Twist connectors until wires are tightly joined together F Wrap each connection with approved electrical tape and carefully stuff all the connecte...

Page 5: ...xcess caulk STEP 7 Apply Silicone Sealer to Backplate A Make sure exterior wall surface and fixture backplate are free of dirt before applying caulk Using exterior grade caulk start on one side of fixture backplate and follow contour where the fixture backplate meets the exterior wall surface upward Proceed to caulk over top of backplate and down other side Do not caulk bottom of fixture backplate...

Reviews: