background image

 

 

 

18 

 

 

 

When memory is full, it will take about two minutes to upload all history data into PC and it takes 

another two minutes to process all history data for graphic display. 
Further detailed PC software user manual can be found from the help menu. 

 

 

Summary of Contents for UGE

Page 1: ...1 UGE WEATHER STATION WIND AND AIR PRESSURE Operation Manual...

Page 2: ...nd the precise radio controlled time information that our instruments offer In particular the included anemometer will highlight the opportunity of installing a Wind Turbine This manual will guide you...

Page 3: ...r humidity 14 Outdoor temperature 15 Outdoor humidity 15 Memory modes 15 Reset to Factory Default Settings 16 PC Connection 16 Data Storage 16 Data Recall 16 Connections and Software 16 PC software in...

Page 4: ...ter independent of altitude INCHES OF MERCURY inHg Inches of Mercury are the common units of measurement for air pressure in the United States HECTOPASCALS hPa Hectopascals are the common units of mea...

Page 5: ...oor Temperature 6 Outdoor Temperature 7 Memory 8 Date 9 Rainfall 10 Weather Forecast 11 Indoor Humidity 12 Outdoor reception signal 13 Outdoor Humidity Note The presence of the Alarm On icon in the se...

Page 6: ...arning mode will be terminated When outdoor transmitter has been registered the base station will automatically switch to the normal display mode from which all further settings can be performed by th...

Page 7: ...ocation Permanent wind direction error will be introduced when the wind direction sensor is not orientated correctly during installation Wind speed sensor wire has to be inserted into the phone jacket...

Page 8: ...8...

Page 9: ...9...

Page 10: ...be positioned in their permanent places Before permanently mounting make sure that all components work properly together at their chosen mounting or standing locations If for example there appears to...

Page 11: ...Press the ENTER key to select the following modes Time zone Note At Europe 0 for GMT 1 time zone 1 for GMT 2 time zone 1 for GMT time zone At America 4 for Atlantic time zone 5 for Eastern Time zone...

Page 12: ...alarm If alarm is enabled an alarm symbol appears in the display indicating the alarm function has been enabled RAIN Press the MENU key the fourth time to select the RAIN section RAIN section digits...

Page 13: ...ssure value When both the pressure value and MAX icon are flashing hold the ENTER key for 3s the maximum pressure value will be reset to current reading Reset the minimum pressure value When both the...

Page 14: ...the eighth time to select the INDOOR TEMPERATURE section INDOOR TEMPERATURE section digits will start flashing Enter the temperature unit mode press the UP or DOWN key to select temperature unit betwe...

Page 15: ...perature unit display Press the UP or DOWN key to select the temperature unit between and by The outdoor temperature high alarm setting Press the ON OFF key to on off the alarm If alarm is enabled an...

Page 16: ...power supply In case the memory capacity of the Weather Station is exhausted the oldest data sets stored will be overwritten by the new ones entered DATA RECALL Certain weather data or setting values...

Page 17: ...the read of all history data into the PC Please note however when there is large amount of data is being uploaded it will take a few minutes time before the system can respond to your setup settings O...

Page 18: ...l it will take about two minutes to upload all history data into PC and it takes another two minutes to process all history data for graphic display Further detailed PC software user manual can be fou...

Page 19: ...range 0 C 50 C 32 F to 122 F show if outside range Resolution 0 1 C Measuring range rel humidity 10 99 Resolution 1 Measuring range air pressure 300 1100hPa 8 85 32 5inHg Accuracy 3hpa under 700 1100...

Page 20: ...licated or processed using electronic mechanical or chemical procedures without written permission of the publisher This handbook may contain mistakes and printing errors The information in this handb...

Page 21: ...nternet Explorer 6 0 or above Processor Pentium III 500 MHz or above Memory at least 128MB 256MB recommended CD ROM Drive Base Station and PC must be connected by USB cable 3 INSTALLATION OF THE EASYW...

Page 22: ...ing changes on the PC software However you can still easily make any setting changes you wanted from the PC and download the changes into the base station the setting change will be refreshed when nex...

Page 23: ...nfiguration This section is used to set up PC software display base station units as well as able or disable the corresponding alarm function Once you made your choice press Save to make the setting e...

Page 24: ...esired time high or low alarm value for the base unit Once you made your choice choose Save to make the setting effective If you don t want to make any change just press Cancel and exit without change...

Page 25: ...25 This section is used to display the recorded min and max value recorded with time stamp Min Max reset can only be done through key operation on the base station display listed history data...

Page 26: ...tation is full press Clear Memory button to refresh the memory space on the base station remember to upload all data before pressing this button If you wanted to start a new weather history record pre...

Page 27: ...can see the history data plotted in graph format for easier observation If you want to see more details just use your mouse to select the area you wanted and the display will be automatically updated...

Page 28: ...28...

Page 29: ...29 Also you can see the graph in 3D mode by selecting the 3D check box...

Page 30: ...on working properly please check the following step 1 find the folder where the EasyWeahter exe file is located 2 Create a file name reg_graph bat file with wordpad or notepad editor program 3 Type re...

Page 31: ...mory on the base station is cleared by manual setting then the history weather data since last uploading is lost permanently Before memory is used up memory icon on LCD display showing 100 full rememb...

Reviews: