19
SPECIFICATIONS
Outdoor data
Transmission distance in open field :
100m(300 feet)
Frequency :
433MHz
Temperature range :
-40°
C--65°
C (-40
℉
to +149
℉
)
Accuracy :
+ / - 1 °
C
Resolution :
0.1°
C
Measuring range rel. humidity :
10%
~
99%
Accuracy :
+/- 5%
Rain volume display :
0 – 9999mm (show --- if outside range)
Accuracy :
+ / - 10%
Resolution :
0.3mm (if rain volume < 1000mm) 1mm (if rain
volume > 1000mm)
Wind speed :
0-160km/h (0~100mph) (show --- if outside
range)
Accuracy:
+/- 1m/s (wind speed< 10m/s), +/-10% (wind
speed > 10m/s)
Measuring interval thermo-hygro sensor:
48 sec
Water proof level :
IPX3
Indoor data
Measuring interval pressure / temperature :
48 sec
Indoor temperature range :
0°
C--50°
C (32°
F to + 122°
F) (show --- if outside
range)
Resolution :
0.1°
C
Measuring range rel. humidity :
10%
~
99%
Resolution :
1%
Measuring range air pressure :
300-1100hPa (8.85-32.5inHg)
Accuracy :
+/-3hpa under 700-1100hPa
Resolution :
0.1hPa (0.01inHg)
Alarm duration :
120 sec
Power consumption
Base station
:
2XAA 1.5V LR6 Alkaline batteries
Remote sensor :
2xAA 1.5V LR6 Alkaline batteries
Battery life :
Minimum 12 months for base station, Minimum
24 months for thermo-hygro sensor
Remark
:
Where outdoor temperature is lower than -20°
C make sure proper type of batteries to be used to
assure that the device can get enough power to maintain its function properly. Normal alkaline
batteries is not allow to be used since when outdoor temperature is lower than -20 °C the battery‘s
discharging capability is greatly reduced.