background image

1

Congratulations:

Thank you for purchasing URC’s TRF-ZW3 Z-Wave Gateway. The TRF-ZW3
communicates with Z-Wave devices and your compatible URC control system,
integrating them seamlessly together into a single user interface for control and
automation. Incorporating this gateway as part of a URC control system offers a myriad
of potential additions to your home.

Easily expand your system by adding virtually any Z-Wave enabled device to your
connected home. Options include URC Lighting and thousands of 3rd party products such
as door locks, thermostats, sensors, and more.

Features and Benefits:

Z-Wave Plus™ Certified

Z-Wave plus and the next generation hardware platform offer enhanced
features, capabilities, stability, and improve the overall experience. For more
information, visit the 

Z-Wave Alliance

 web-site.

Improved performance features include:

Network wide inclusion (pairing) allows for easier installation and
expansion.

Enhanced self-healing for improved reliability and user experience.

Improved battery life.

Improved range creates a more robust network.

UI 7 Programming:

Intuitive programming and control of Z-Wave devices. The platform includes
URC Lighting specific programming such as simplified device options,
EZ-associations, and more.

Summary of Contents for TRF-ZW3

Page 1: ......

Page 2: ...atibility 2 Device Layout and Connections 3 LED Indicator Lights 5 Installation 7 Using the TRF ZW3 7 Including pairing a Device 7 Excluding a Device 8 Restricting Installer Access 9 Hardware Specifications 10 Warranty Statement 10 Table of Contents ...

Page 3: ...ts such as door locks thermostats sensors and more Features and Benefits Z Wave Plus Certified Z Wave plus and the next generation hardware platform offer enhanced features capabilities stability and improve the overall experience For more information visit the Z Wave Alliance web site Improved performance features include Network wide inclusion pairing allows for easier installation and expansion...

Page 4: ...e Bluetooth devices must be included in the UI7 programming portal library Control of these devices is limited and not supported by URC Learn more about supported device by clicking here Compatibility The TRF ZW3 can work independently without any of URC s control systems However this builds a system designed to only control Z Wave devices In conjunction with URC s line of control systems Z Wave c...

Page 5: ...d by blinking the corresponding LED light Wi Fi Radio After pressing the Sync button press the Select button once The Wi Fi LED starts to blink indicating that the WPS feature can be selected Press the Sync button again to start the two 2 minutes WPS countdown Include Exclude Radio When the select button is pressed a second time the Z Wave LED starts to blink This indicates that the Z Wave Include...

Page 6: ...be pressed with a paperclip Reset Network Settings Press the button three 3 times within six 6 seconds Factory Reset Press the button six 6 times within six 6 seconds Power Cycle Shutdown Press n hold the button for 30 seconds to shutdown the unit and then disconnect the gateway from its power supply 6 ...

Page 7: ... available states LED On Gateway is connected via Ethernet LED Off Gateway is not connected via Ethernet LED Flashing Gateway cannot connect to the Internet c Wi Fi LED Three 3 available states LED On Wi Fi enabled LED Off Wi Fi disabled LED Flashing WPS is active d Z Wave LED Four 4 available states LED On Z Wave radio is enabled LED Off Z Wave radio is disabled LED Flashing slow once per second ...

Page 8: ...available states LED On Function has been enabled LED Off Function has been disabled LED Flashing slow The gateway is in inclusion pair mode LED Flashing fast ZigBee device was successfully included added g Bluetooth LED Provides information on the status of the Bluetooth radio Four 4 available states LED On Function has been enabled LED Off Function has been disabled Flashing slow Gateway is in s...

Page 9: ...tal Manually Including pairing and Excluding removing Z Wave Devices Z Wave devices are normally paired or unpaired with the Z Wave gateway via the web portal UI7 however it is possible to complete the process manually Including pairing a Device manually 1 Press the Sync button once page 3 The Z Wave light blinks slowly once every second to indicate that it is in pairing mode 2 Follow the pairing ...

Page 10: ...r the Z Wave device 3 When the device has been successfully unpaired the Z Wave LED flashes rapidly for less than a second then returns to the exclusion state 4 Pressing the Sync button once returns the gateway to the inclusion state Press the button a second time to return the gateway to its normal operating mode It is significantly faster to exclude devices using the manual method rather than th...

Page 11: ...An email is sent to the end user s email address containing a link to setup their Z Wave account Use that link to complete the end user s account setup URC recommends restricting this access Follow these steps after completing the initial setup of your Z Wave account 1 Log into your user account at www urc mios com 2 Select Settings from the column of options at the left 3 Choose Customer Care fro...

Page 12: ... by the end user but no longer than forty eight 48 months from the date of shipment of the URC equipment by URC to an authorized URC dealer or distributor This limited warranty is valid only in the United States of America URC equipment purchased from other than an authorized URC dealer or distributor is without warranty URC warrants that the software will substantially conform in any material res...

Page 13: ...ply to the maximum extent permitted by applicable law In the event of any warranty claim URC will at its sole option repair the URC equipment using new or comparable rebuilt parts or exchange the URC equipment for new or rebuilt equipment In the event of a defect these are the end user s exclusive remedies All the URC equipment returned for service exchange or repair require an RGA number To obtai...

Page 14: ...UTER SYSTEMS OR COMPUTER PROGRAMS URC S LIABILITY IF ANY FOR DIRECT DAMAGES OF ANY FORM SHALL BE LIMITED TO ACTUAL DAMAGES NOT IN EXCESS OF AMOUNTS PAID BY END USER FOR THE URC EQUIPMENT IN NO EVENT SHALL URC BE LIABLE FOR ANY EVENTS BEYOND ITS CONTROL INCLUDING ANY INSTANCE OF FORCE MAJEURE IN NO EVENT SHALL URC BE LIABLE FOR THE ACTS OR OMISSIONS OF END USER OR ANY THIRD PARTY THE LIMITATIONS OF...

Page 15: ...ial installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be deter...

Page 16: ... changes or modifications not expressly approved by the party responsible for compliance could void the authority to operate equipment The antenna s used for this transmitter must not be co located or operating in conjunction with any other antenna or transmitter Federal Communication Commission FCC Radiation Exposure Statement This remote device is approved as a hand held and hand operated only p...

Reviews: