background image

SPEC. 

Classi. 

Item  

SPECIFCATIONS 

 

Power Unit 

Rated input voltage 

85V AC ~ 265V AC (Universal voltage) 

Output Voltage 

85V AC ~ 265V AC (Universal voltage) 

Driving Type 

Electronic Type 

Max. Output 

4 kw  

Load 

No. of circuit 

1 circuit 

Max. Capacity 

18A (Resistive Load) 

Degree of 
Precision 

Degree of Temp Precision  

±

 1

 ; Change of 1

 /30sec (Delay Option 20 sec) 

 

 

Motion  

Power input display 

FND Temp Display 

Output Display 

RUN RED is ON (Red) 

Temp Range 

Possible to choose within the range of -9 

  ~ 80 

  

Output Delay(Option) 

01 sec ~ 60 sec 

 

 

Sensor 

Types 

NTC: Negative Temperature Coefficient  Epoxy Molding 

Degree of Precision % 

1 % 

25 

’s rating resistance  

5000 ohm, Beta Constant = 4000 

0

 K 

Quantity  

SENSOR 1: for sensing Temp,  SENSOR  2:  for checking Overheating (Option) 

 

Function 

(Capacity) 

Safety 
Device 

Snapping / Short circuit  

of Sensor Wires 

If Temp Sensing Sensor is snapped, converted to Timer mode automatically and work 
If short Circuit, “ES” displays and output is OFF 

Overheating Prevention 
Sensor(OPTION) 

If overheating sensing temp is higher than that of set overheating temp, “Ht (Overheat)” displays and output is shut 
off.  

Fuse Resistance  

10 ohm (for controller internal circuit protection) 

 

 

Others 

External Case 

Flame Retarding  

Weight   

270 g  

Dimensions (mm) 

70(W) 

×

 120(H) 

×

 27(D) 

Use Temp 

Air Temp 

 ~ 40 

 

Air Humidity 

Under 80 % 

Summary of Contents for UTH-170R

Page 1: ...Manual for Use and Installation UTH 170R ...

Page 2: ...Connection and Fixing Fixing Connection Method 1 ...

Page 3: ...Connection and Fixing Fixing Connection Method 2 ...

Page 4: ...ols the controller power ON OFF and sets temp set UP DOWN Use the remote control toward the front The function of fine setting motion or the sequence motion is intentionally removed for reducing the occurrence of malfunction For fine setting please use the keys on the controller How to Set Set if necessary to change the range of set temp finely tn displays on the Temp display Screen after pushing ...

Page 5: ...verheating sensor sensing temp exceeds the set temp OPTION Correction Temp Set ES 00 9 10 Scope for correcting the actual temp deviation Table 1 Sensor Mode TIMER Functions Must disconnect the temp sensor for using timer functions see Table 2 Push and keys simultaneously for 3 sec tn displays Push key once again the EN displays EN as the mode by sensor is same to the present mode Push key once aga...

Page 6: ...ickers the cycle value is saved and the present intensity displays How to set serviceman push and keys simultaneously tn displays on the screen select tin push and keys simultaneously Cycle value d splays Cycle select Cycle basic 3 min Set cycle value push and keys simultaneously AU flickers saved It is recommended for the end user not to set How to use by the end user select the intensity to be u...

Page 7: ...perature Coefficient Epoxy Molding Degree of Precision 1 25 s rating resistance 5000 ohm Beta Constant 4000 0 K Quantity SENSOR 1 for sensing Temp SENSOR 2 for checking Overheating Option Function Capacity Safety Device Snapping Short circuit of Sensor Wires If Temp Sensing Sensor is snapped converted to Timer mode automatically and work If short Circuit ES displays and output is OFF Overheating P...

Reviews: