CALIBRATION PROGRAMS
It is used to initialize the new machine and re-
move the old equipments’ measurement errors
caused by total loss from use , parts ageing and
replacing, or strong impact.
Calibration procedures include unbalance cali-
bration and automatic gauge calibration.
Press
Stop
Stop
Apagado
Apagado
or
key to exit calibra-
tion program.
UNBALANCE CALIBRATION
Choose a wheel with small unbalanced value
and install it on the balancer. Input the wheel
parameters then calibrate.
Press button “ FINE” 3
seconds show
Add,0,0,then lose hand.
Press START the first time
,rotating
machine.
At 12 o’clock position of
outside wheel strike 100g
weights ( outside 5 indi-
cator lights all brighten )
Press again the second
time ,rotating machine
At 12 o’clock position of
inside wheel strike 100g
weights (inside 5 indicator lights all brighten )
The third time ,rotating machine ,calibration
complete automatically preserve the result
after finishing measure automatically return
back original state after finishing measure.
29
Enter the setting
Guard control
setting.
Standarization display
setting.
The least value setting of
unbalancing.
Buzzer switch setting
Width input unit setting
Diameter input unit setting
Unbalanced weight
unit setting
Press during 30 seconds to
enter the setting.
ON / OFF to turn off or turn on the
guard control.
Set the pace to 1g/5g or 0.1oz0.25oz,
the result of the measurement will be
shown by the multiple set.
This is set between 1g-40g o
0.1o1.5oz, smaller than what will be
shown “0”
ON / OFF to start or stop the buzzer’s
sound announcement
“0” means inch as unite
“0” means mm as unite
“0” means inch as unite
“0” means mm as unite
“Gr”means gram as unit
“Oz”means ounce as unit
Save and exit
Exit