background image

10

Drain water from air compressor tank and 

condensation from air lines. See air compres-

sor’s operation manual.

     CAUTION

 Disconnect the tool from the air 

supply before lubricating, installing, removing 
or adjusting the tool.

•Lubricate tool, see “Maintenance“ section in 

this manual.

•Select the required impact socket. Use exten

-

sion anvil only when needed.

•Connect  tool  to  air  hose  of  recommended 
size. 

NOTE: The use of a quick connect set makes 
connecting easier.

IMPORTANT:

 The use of air filters and air line 

lubricators is recommended.
To use:

•Turn air compressor on and allow air tank to 

fill.

•Set  the  air  compressor’s  regulator  to  90  PSI 

(6.2 bars). This tool operates at a maximum 90 
PSI (6.2 bar) pressure.

•Set torque regulator to fit the desired setting 

to avoid over tightening.

       IMPORTANT:

 These torque values can vary 

depending  on  the  size  of  the  air  compressor 

and the cubic feet of air the air compressor 
delivers.

•Do not use damaged, frayed or deteriorated 

air hoses and fitting.

•Depress the trigger to operate tool.
•Release trigger to stop tool.
•Always disconnect air supply when before lu

-

bricating, installing, removing or adjusting the 
tool.

•When job is complete, turn the air compressor 

off and store as described in the air compressor 
operator manual.

•Always use clean, dry air at 90 PSI (6.2 bars) 

maximum air pressure. Dust, corrosive fumes 
and/or excessive moisture can ruin the internal 
components of a pneumatic tool.

•Do not remove any labels. Replace and dam

-

aged label.

•Keep  hands,  loose  clothing  and  long  hair 

away from rotating end of tool.

 MAINTENANCE

Lubrication

Air tools require regular lubrication through-
out the life of the tool. The air motor and bear-

ing uses compressed air to power the tool. Be

-

cause moisture in compressed air will rust the 

air motor, you must lubricate the motor daily. 
An inline oiler is recommended.

To lubricate the air motor manually:
•Disconnect the tool from the air supply hold

-

ing it so the air inlet faces up.

•Depress  the  trigger  and  place  one  to  two 

drops of air tool oil in the air inlet. 

•Connect  the  tool  to  an  air  source,  cover  the 

exhaust end with a towel and run for a few 
seconds.

•Do not lubricate tools with flammable or vol

-

atile liquids such as kerosene, diesel or jet fuel

 TECHNICAL DATA

AIR PRESSURE
SHOOT GAUGE
LENGTH STAPLES

CROWN

STAPLES CAPACITY

WEIGHT

70-100 PSI
16 cal

3/8” - 2”
7/16”

50 PIECES
2,2 kg (4,85 lb)

EN650 manual.indd   10

06/07/15   11:57

Summary of Contents for SURTEK EN650

Page 1: ...n este manual antes de operar esta herramienta WARNING Read understand and follow the safety rules in this manual before operating this tool EN650 Engrapadora Neum tica Air Stapler Manual de Usuario y...

Page 2: ...ation Maintenance Technical data Notes Warranty Normas generales de seguridad Sistema de Aire Comprimido Instrucciones de operaci n Operaci n Medidas de Precauci n Mantenimiento Problemas y soluci n D...

Page 3: ...nta ni a usted ni a ninguna otra persona Nunca dispare un grapa a una superficie dura o quebradiza como el concreto acero o tejas No apunte los grapas muy cerca del borde de la pieza de trabajo o con...

Page 4: ...nos ruido generado Reducci n en el desgaste de la herramienta Al presentarse cualquier defecto o un fun Diferentes piezas de trabajo requerir n dife rentes presiones de operaci n entre mas fuer te la...

Page 5: ...a herramienta esta deber ser desconectada de la fuente de aire comprimido y pasarse a un especialista para su inspecci n Siempre asuma que la herramienta contiene grapas Quite el dedo del gatillo cuan...

Page 6: ...e muy baja Checar compresor PROBLEMAS Y SOLUCI N Anillo del pist n desgastado Reemplazar anillo del pist n Amortiguador del pist n desgastado Hacer una prueba ideal y verificar el regreso del embolo d...

Page 7: ...ta do o roto Superficie interna del cilindro desgastada o rugosa Desensamble la unidad de salida y verifique las superficies internas y externas del anillo del pist n y del cilindro Reemplace las part...

Page 8: ...followed to reduce the risk of personal in jury Risk of eye or head injury Air powered equipment and power tools are capable of propelling materials such as metal chips saw dust and other debris at h...

Page 9: ...in jury to self or others Use clamps or other devices to prevent move ment Never operate tool while under the influence of drugs or alcohol Don t overreach Keep proper footing and balance at all times...

Page 10: ...installing removing or adjusting the tool When job is complete turn the air compressor off and store as described in the air compressor operator manual Always use clean dry air at 90 PSI 6 2 bars maxi...

Page 11: ...11 Manual de usuario User s manual Notas Notes EN650 manual indd 11 06 07 15 11 57...

Page 12: ...odified by unauthorized or unqualified person Urrea Herramientas Profesionales S A de C V garantiza este producto por el termino de 1 a o en sus piezas componentes y mano de obra con tra cualquier def...

Reviews: