- 9 -
Steps are as follows:
●Remove top panel, and needle type pressure
joint screw arbor (Fig.2), then slip rubber tube
of pressure gauge over needle type pressure
joint;
●Start the equipment in accordance with the
instructions, measuring gas supply pressure
(dynamic pressure) in the work state;
●Access to the equipment if measured data
within the limits of Table 1, otherwise, you will
need to adjust gas pressure regulating valve or
contact gas supplier to bargain; Fig.2
●Unplug pressure gauge after you accomplish pressure testing, then install needle
type pressure joint screw arbor.
Important: make sure to screw the needle
valve to prevent gas escape!
Debugging
It’s very important to debug the new stove. Through the comprehensive system test
of equipment, we can ensure function and safety performance of products. Discovering
any potential problems before use (such as equipment’s placement, ventilation,
operation, etc.), can avoid costly losses.