SYSTEM MAINTENANCE
US Filter
25
2.
Change prefilter when the differential pressure is greater than 0.69 bar
(10 psi) or every month, whichever occurs sooner.
3.
Inlet pressure regulator screen should be cleaned once a month.
D.
Pump
1.
Check pressures daily; record weekly.
2.
If the pressures have fallen off, check product and reject flows.
E.
Conductivity
1.
Observe feed and permeate conductivity daily; and record weekly.
2.
Record percent salt rejection weekly.
F.
Flow Rates
1.
Check daily and record permeate and reject flow rate weekly.
2.
Calculate the percent recovery using the following formula:
Permeate Flow Rate
100 X
= % Recovery
Permeate Flow Rate + Reject Flow Rate
The percent recovery should not exceed the design value shown on the
System Specifications sheet in the Appendix. If minimizing water usage
is critical, the percent recovery should be maintained near, but not above
the maximum value. Operating with too high a percent recovery will lead
to premature fouling of the membrane.
G.
Calcium
Measure the feed and permeate calcium and calculate the percent rejection
using the following formula:
Calcium Inlet - Calcium Permeate
100 X
= % Ca Rejection
Calcium Inlet
H.
Bacteria
Measure the number of bacteria from the permeate line weekly. Record the
results as colony forming units per milliliter (CFU/ml). Sanitize as necessary.
I.
If the maintenance log shows steady deterioration in results (product flow,
percent rejection, etc.) corrective action should be taken. (Described in section
5.0 Troubleshooting.)