-8-
NOTE: Dimensions from the floor to your stoves
inlet/exhaust pipes are approximate and may vary
depending on your installation.
FIGURE 9
TYPICAL FRESH AIR TERMINATION
SPECIAL MOBILE HOME REQUIREMENTS
•
WARNING! - Do not install in a sleeping room.
•
CAUTION! - The structural integrity of the mobile home floor,
wall, and ceiling/roof must be maintained.
In addition to the previously detailed installation requirements,
mobile home installations must meet the following requirements:
•
The unit must be secured to the floor using lag bolts in the
holes provided in the pedestal base.
• The heater must be electrically grounded to the steel chassis
of the mobile home with 8 GA copper wire using a serrated
or star washer to penetrate paint or protective coating to
ensure grounding.
•
Vent must be 3 or 4-inch “PL” Vent and must extend a
minimum or 36 in.(914mm) above the roof line of the mobile
home and must be installed using a UL listed ceiling fire stop
and rain cap.
• When moving your mobile home, all exterior venting must
be removed while the mobile home is being relocated.
After relocation, all venting must be reinstalled and
securely fastened.
• Outside Air is mandatory for mobile home installation. See Outside Air Supply section and your dealer for
purchasing.
•
Check with your local building officials as other codes may apply.
Mobile Home Mounting
Bolt Hole
Mobile Home
Mounting Bolt Hole
Attention:
DO NOT vent under any porch, deck, awning, or in any semi enclosed or roofed area. Doing so
may result in unpredictable airflow at the vent cap under certain conditions and can affect the performance
of your stove, as well as, other unforeseeable issues.