22
Programming
Installation, Operation and Maintenance Manual
Models: 089-IF-150, 089-IF-250, 089-IF-400,
089-IF-500
Main Menu
Use the “UP or DOWN” arrows to move the cursor over
“Regen. Time Setting” and press the “Set” button.
Use the UP or DOWN” arrows to change the duration to 1:00 AM or a
least 1 hour after water usage has stopped for the day. Most water
softeners are set to regenerate at 2:00 AM so the backwashing filter
should be set for 1 hour before the softener is set to regenerate. This
will ensure the backwash is complete prior to the potential water softener
regeneration. Once the hour value is adjusted, press the “Set” button,
then set the minute value, press the “Set” button again, then set the 12
cycle (AM or PM) and press the “Set” button to save the value then press
the “Menu” button to confirm the change and return to the “Main Menu”.
Use the “UP or DOWN” arrows to move the cursor over
“Regen. Days Setting” and press the “Set” button.
Use the “UP or DOWN” to change the “Days” to “20” initially. The inlet
and outlet gauges are used to determine that actual setting. When the
system is installed the service pressure drop should be recorded.
Once the pressure drop increases 6-10 PSI over the service pressure
drop the days of use should be recorded. The filter should be
regenerated that night and the “Days” setting should then be changed
to 1 day less than the recorded days. This will ensure the system
backwashes before the pressure drop is observed. Once the days are
changed, press the “Set” button to save it and then press the “Menu”
button to confirm the setting and return to the “Main Menu”. Press the
“Menu” button again to return to the “User Settings”.
=====Main Menu=====
Regen. Time Setting
Regen. Days Setting
Advanced Menu
=====Regen. Time=====
1:00 AM
Press [ ] To Cancel ,
Press [ ] To Confirm
=====Main Menu=====
Regen. Time Setting
Regen. Days Setting
Advanced Menu
=====Regen. Days=====
20 Days
Press [ ] To Cancel ,