5. Tank in Service (Display Code TS)
Press the Extra Cycle button. Use this display to set whether tank one or tank two is in service. This option setting is identified
by “TS” in the upper left hand corner of the screen. This parameter is only available if the number of tanks has been set to 2.
There are two possible settings:
Tank One in Service: U1 Tank Two in Service: U2
NO CHANGES NECESSARY ON THIS PARAMATER
6. Unit Capacity (Display Code C)
Press the Extra Cycle button. Use this display to set the Unit Capacity. This setting specifies the treatment capacity of the system
media. Enter the capacity of the media bed in grains of hardness when configuring a softener system, and in the desired volume
capacity when configuring a filter system. This option setting is identified by “C” in the upper left hand corner of the screen. The Unit
Capacity parameter is only available if the control type has been set to one of the metered options. Use the Up and Down buttons to
adjust the value as needed.
Range: 1-999,900 gallons (100-9,999,000 Liters)
Use the following chart to determine your capacity setting.
Low Salt Settings
Medium Salt Settings
High Salt Settings
System Size
Capacity
Setting
Brine Fill
(mins.)
Capacity Setting
Brine Fill
(mins.)
Capacity
Setting
Brine Fill
(mins.)
26,000
Grain
15,000
4
18,000
6
24,000
8
35,000
Grain
20,000
4
25,000
8
30,000
10
53,000
Grain
30,000
6
37,000
10
45,000
14
70,000
Grain
40,000
8
50,000
16
60,000
20
88,000
Grain
50,000
10
63,000
18
75,000
25
105,000
Grain
60,000
12
75,000
20
90,000
30
140,000
Grain
80,000
16
100,000
28
120,000
40