21
REVISION 1.0, 1-19-15
ABNORMAL PERMEATE FLOW
Permeate flow should be within 20% of the rated production, after correcting
the feed water temperatures above or below 77°F.
NOTE: TO DETERMINE THE TEMPERATURE CORRECTION FACTOR, LO-
CATE THE TEMPERATURE CORRECTION TABLE ON THE FOLLOWING
PAGE AND FOLLOW THE DIRECTIONS.
Example:
5 gpm @ 59˚ F (5÷1.42=3.52 gpm) 5 gpm
@ 77˚ F (5÷1=5 gpm)
5 gpm @ 84˚ F (5÷0.89=5.62 gpm)
SERVICE ASSISTANCE
If service assistance is required, please complete the following process:
Contact US Water Systems. Prior to making the call, have the following information avail-
able: system installation date, serial number, daily log sheets, current operating parame-
ters (e.g. flow, operating pressures, pH, etc.) and a detailed description of the problem.