5
REVISION 1.0, 1-19-15
DISCONNECT THE ELECTRICAL POWER BEFORE WORKING ON THE UNIT.
NEVER ALLOW THE PUMP TO RUN DRY.
NEVER ALLOW THE UNIT TO FREEZE OR OPERATE WITH A FEED WATER TEM-
PERATURE ABOVE 100°F.
FEED WATER AND OPERATION SPECIFICATIONS
NOTE: IT IS VERY IMPORTANT TO MEET THE MINIMUM FEED
WATER REQUIREMENTS. FAILURE TO DO SO WILL CAUSE
THE MEMBRANE TO FOUL PREMATURELY AND VOID THE
MANUFACTURER’S WARRANTY.
OPERATING LIMITS
Operating Parameters:*
Feed Water Requirements:**
**If any of the feed water parameters are not within the limits given, consult your local dealer or
distributor for assistance.
Feed Temperature
40 - 85°F
System Inlet Pressure
45 - 85 PSIG
Maximum Operating Pressure (@77°F)
120 PSIG (Nominal)
Maximum SDI Rating
< 3
Maximum Turbidity
1 NTU
Maximum Free Chlorine and/or Chloramines
0 PPM
pH (continuous)
3 - 11
pH (cleaning - 30 min.)
2 - 12
NOTE: HIGHER TDS AND/OR LOWER TEMPERATURES WILL RE-
DUCE THE SYSTEM’S PRODUCTION. 2% OF THE SYSTEM OUT-
PUT CAN BE LOST FOR EVERY DEGREE “F” BELOW 77.
Summary of Contents for L1-200
Page 1: ...1 REVISION 1 0 1 19 15 US Water Systems 300 GPD Premium Wall Mount Light Commercial RO System...
Page 9: ...9 REVISION 1 0 1 19 15...
Page 10: ...10 REVISION 1 0 1 19 15...
Page 11: ...11 REVISION 1 0 1 19 15...
Page 12: ...12 REVISION 1 0 1 19 15 SYSTEM IDENTIFICATION...
Page 17: ...17 REVISION 1 0 1 19 15 SPECIFICATIONS...
Page 24: ...24 REVISION 1 0 1 19 15 SYSTEM DRAWING...
Page 25: ...25 REVISION 1 0 1 19 15 L1 300 FLOW DIAGRAM...
Page 26: ...26 REVISION 1 0 1 19 15 L1 SERIES ELECTRICAL SCHEMATIC 110V 60HZ...
Page 27: ...27 REVISION 1 0 1 19 15 L1 SERIES ELECTRICAL SCHEMATIC 220V 50HZ...