background image

26

 

 

DB9  joint  is  for  the  connection  with  other  communication 

equipment 

Connect pins are assigned as the followings: 

  PIN2=TXD

PIN3=RXD

PIN5=GND 

Setting Pattern: 

Data bits 8, without odd-even check, stop bit 1, baud rate is 

adjustable

 

 
 
 
 
 
 
 

 

7.2 RS232 FORMAT 

  Three print formats-Continuous, pressing key and stable 

 

G/W:        92.6 g                G/W gross weight, T/W net weight 

U/W: 0.92625 g                U/W unit weight 

QTY:          100 PCS          QTY quantity 

    Accumulated Print Format

 

No.01                                  The first accumulated total 

G/W:        92.7 g     

U/W: 0.92658 g     

Summary of Contents for Army iCount US-iC Series

Page 1: ...1 Electronic Counting Scale Manual ...

Page 2: ...ON 4 2 1 BODY INSTALLATION 2 2 BATTERY REPLACEMENT 3 INSTRUCTION 5 3 1 PARAMETERS 3 2 POWER SUPPLY 4 DISPLAY 6 4 1 PANEL DESCRIPTION 4 2 KEY DESCRIPTION 4 3 DISPLAY DESCRIPTION 5 OPERATION 9 6 FUNCTION SETTING 20 7 RS232 OUTPUT FORMAT 25 8 ERROR MESSAGES 27 9 SPECIFICATIONS 28 10 WARRANTY 28 ...

Page 3: ...work well you must read the manual carefully before using 1 ATTENTION l Do not let anything drop onto the pan l Do put the scale in a dangerous enviornment l Keep the scale in a level area unobstructed by objects l Do not count pieces on the scale or move around the pan l Keep the scale clean If the product is not going to be used for a long period of time recharge the battery once a month When th...

Page 4: ...e product 2 Connect the AC adapter to an independent power supply to avoid interference from other equipment 3 Scale pan must be empty when turning on the scale 4 The first time setting up the scale wait 3 5 minutes for the scale to autocalibrate 5 For best weighing accuracy the center of gravity for an object should be placed in the center of the pan and not in the corner or edge of pan 2 INSTALL...

Page 5: ...f the stainless steel pan open the housing and disconnect the battery connectors 2 Install the new battery in same position and connect negative and positive poles correctly Warning The positive and negative poles of lead acid battery installed incorrectly can cause a short circuit or electrode reverse which will damage the battery and may cause a fire Connection Red wire to red pole and black wir...

Page 6: ...er of Division 3000 300000 d 3000d dual range approved Working Voltage 5V Sample Rate 20 times Sec Resolution 1 million 3 2 POWER SUPPLY AC Adapter Input 100V 240V Output 12V 1A Battery Specification 6V4AH 4 DISPLAY 4 1 PANEL DESCRIPTION US iC Panel ...

Page 7: ...it weight ON OFF Powers unit on or off TARE Perform Tare Function ZERO Perform Zero Setting Function PRINT Perform Print Function UWS Confirm the input unit weight value CK Cooperate with other keys to set the upper lower limit RETURN Return to weighing interface when setting M HI 1 Perform accumulation function in weighing mode then the symbol M is bright 2 Cooperate with check weight key to inpu...

Page 8: ...ice The time for pressing any key is less than 1 second 4 3 DISPLAY DESCRIPTION No Description No Description 1 Stable Symbol 7 MR Symbol 2 Zero Symbol 8 MC Symbol 3 Symbol 9 R1 cap Symbol 4 NET Symbol 10 R2 cap Symbol 5 Battery Symbol 11 Samples Lack 6 M Symbol Input Unit Weight Lack Weight Unit Weight COUNT 1 2 3 4 5 6 7 8 9 10 11 ...

Page 9: ...he scale 5 2 COUNTING MODE There are three display windows in the US iC series scale in which weight unit weight and count are displayed 5 3 AVERAGE UNIT WEIGHT SETTING If average unit weight was not set beforehand 0 will be displayed in the unit weight and count screen Sampling 1 Place a samples onto the weighing pan 2 Input the number of samples by numeric keyboard and then input numbers are dis...

Page 10: ...reen and NET symbol is displayed 3 Put samples inside the container 4 Input the number of samples by numeric keyboard and the number is displayed on unit weight screen 5 Press SMPL key to display the unit weight value on unit weight screen and sampling value on count screen Input a known average unit weight 1 A known unit weight is input then press UWS key to display unit weight value on unit weig...

Page 11: ...rforming accumulative operation 1 Sampling and count according to the item 5 3 2 Press M HI key to display present accumulated times for short time on unit weight screen and one second later automatically return in counting interface 3 The multiple accumulative operation can be performed by the step 2 5 5 REDISPLAY FUNCTION The redisplay function can be used to check accumulated results and to exa...

Page 12: ...ss continuously ZERO key to examine the information of 10 times accumulated results in descending order 4 Press continuously TARE key to examine each information of 10 times accumulated results in ascending order 5 Press RETURN key to return in counting interface 5 6 CLEAR ACCUMULATION FUNCTION Clear Accumulation Function can be used to clear the accumulated results and the accumulated value each ...

Page 13: ...ults in descending order and press MC key to clear the present accumulated information 4 Press continuously TARE key to examine the information of 10 times accumulated results in ascending order and press MC key to clear the present accumulated results 5 Press RETURN key to return to counting interface 5 7 CHECK WEIGHT Check Weight mode and check weight alarm range function can be set under functi...

Page 14: ...ight by numeric keyboard press SMPL key to confirm the lower limit weight 3 Press M HI key to display check weight alarm range on weight screen upper limit weight on unit weight screen HI on count screen Change the upper limit weight by numeric keyboard press SMPL key to confirm the upper limit weight 4 Press RETURN key to return in counting interface 5 Press CK key and press RSMPL key again to op...

Page 15: ...unt screen 2 Press MR LO key to display check count alarm range on weight screen lower limit count on unit weight screen LO on count screen Change the lower limit count by numeric keyboard press SMPL key to confirm the lower limit count 3 Press M HI key to display check count alarm range on weight screen upper limit count on unit weight screen HI on count screen Change the upper limit count by num...

Page 16: ... calibrate the scale in working conditions 1 In the power off mode hold on SMPL key and press ON OFF key to enter in function setting and display set on weight screen 0 on unit weight screen 2 Input 1139 by pressing numeric keys and press SMPL key to display CAL on weight screen 1Point on unit weight screen C ZEro on count screen 3 Confirm there is no load on the pan and press TARE key to perform ...

Page 17: ...hing interface 5 10 UNIT SETTING unapproved In general the unit will not need to be reset because they were already set before delivery If setting up is needed the steps are shown in g kg 1b oz Notice The units kg and g are only allowed by rules to be legal measure unit 1 In the of power off mode hold down SMPL key and press ON OFF key to enter in function setting display set on weight screen and ...

Page 18: ... the followings Notice Minimum Zero Display 0 is only allowed to be set on rules 1 In the condition of power off hold on SMPL key and press ON OFF key to open function setting display SET on weight screen and 0 on unit weight screen 2 Input 1136 by numeric keys and press SMPL key to display Auto Z on weight screen 1136 on unit weight screen Minimum Zero Display on count screen 3 Press 1 key to cha...

Page 19: ...r calibration was done before delivery Notice please calibrate the scale in working conditions 1 In the condition of power off hold on TARE key and press ON OFF key to enter in linear calibration interface and display CAL on weight screen LinE on unit weight screen C ZEro on count screen 2 Confirm no load on the pan press TARE key to set zero point calibration display 1 3 maximum capacity on count...

Page 20: ...s TARE key to count backwards to return in weighing interface 6 FUNCTION SETTING In the condition of power off hold on ZERO key and press ON OFF key to enter in function setting interface and display SCALE on weight screen FunC on unit weight screen SET on count screen 6 0 BACKLIGHT SETTING Press 0 key to display FunC0 on weight screen LiGh on unit weight screen backlight type on count screen Pres...

Page 21: ... 5 anti vibration level The bigger the number is the more vibration proof it is 6 2 BAUD RATE SETTING Press 2 key to display FunC2 on weight screen bAud on unit weight screen baud rate value on count screen Press 2 key to change the different baud rate 9600 19200 4800 6 3 CHECK WEIGHT BUZZER SETTING Press 3 key to display FunC3 on weight screen CK bz on unit weight screen ON or OFF on count screen...

Page 22: ...ight Hi over upper limit alarm red light Lo under lower limit alarm yellow light 6 5 CHECK WEIGHT COUNT SETTING Press 5 key to display FunC5 on weight screen CK S on unit weight screen WEiGH PCS on count screen Press 5 key to change them WEiGH check weight mode PCS check count mode 6 6 PRINT SETTING Press 6 key to display FunC6 on weight screen Prt on unit weight screen Print Pattern on count scre...

Page 23: ...ount screen Press 7 key to change them K P205 connect to K P205 printer SCr connect to large screen display PC connect to computer dot MA connect to micro printer 6 8 LARGE SCREEN DISPLAY PATTERN SETTING Press 8 key to display FunC8 on weight screen SCrEEn on unit weight screen Display Pattern on count screen Press 8 key to change them PCS Large screen display PCS number WEiGht Large screen displa...

Page 24: ...ccording to value of internal code 6 11 RS232 OUTPUT ACCUMULATED MESSAGE SETTING Press RSMPL key to display Pr ALL on weight screen on unit weight screen SET MP on count screen Press M HI key to change them Pr ALL in count interface press M HI key to print and output every accumulated value press MR LO key to display the accumulated total message and press PRINT key to print and output the accumul...

Page 25: ...n be printed and output 1 Press M HI key to change the display nP Wt on weight screen Don t output weight message 2 Press MR LO key to change the display nP UWt on weight screen Don t output unit weight message 3 Press MC key to change the display nP PCS on weight screen Don t output count message To set above function as requirement and press SMPL key to confirm the setting then to count backward...

Page 26: ...D Setting Pattern Data bits 8 without odd even check stop bit 1 baud rate is adjustable 7 2 RS232 FORMAT Three print formats Continuous pressing key and stable G W 92 6 g G W gross weight T W net weight U W 0 92625 g U W unit weight QTY 100 PCS QTY quantity Accumulated Print Format No 01 The first accumulated total G W 92 7 g U W 0 92658 g ...

Page 27: ... accumulated total U W 0 92658 g QTY 300 PCS Count of accumulated total 8 ERROR MESSAGE Symptom Possible Reason Solution Unable to boot No power or dead battery Check power and battery connection Can t be calibrated Hostile working condition Unsuitable weight Working condition Suitable weight W over Exceed maximum capacity 9d Lessen objects LOW BAT Dead battery Charge battery Battery Battery is lo...

Page 28: ...sion Specifications on demand Capacity 3kg 6kg Division 0 01g 0 05g Capacity 15kg 30kg Division 0 1g 0 1g symbol P2 Err Exceed 20 max capacity Take down the load AC Err The accumulated times exceed 10 Clear the accumu lated times Not Zeroing Hostile working condition Touch the pan Load cell damaged or PCB problem Working condition Eliminate objects Repair in factory ...

Page 29: ...ts excluding the battery Parts that prove to be defective will be covered under the warranty at no extra charge unless damage is caused by misuse of product To make a warranty claim for replacement parts the customer must submit the original invoice along with pictures and or a video of the problems In the following situation you must pay for the item in advance for repair if 1 The damage was caus...