Page 4
Default Reset :
Following this procedure will set all System Programming Parameters to factory default settings.
1. Enter System Programming.
2. Press Transmitter Button 3.
(
In Factory Upgrade Mode turn ignition switch Off then back On 3 times
)
·
The siren will chirp 6 times indicating that the reset signal was received.
·
All System Programming parameters are now set to factory default settings.
·
The Valet Mode is off.
·
The optional Disarm Code will reset.
3. Turn off ignition.
Optional Coded Emergency Override:
As an extra measure of security, the system is equipped with an optional Coded Emergency Override
feature. Once an Emergency Override Code is chosen and programmed during installation, the system
can no longer be disarmed using the standard override procedure.
To Emergency Override the system using the Code:
1.Follow steps 1-3 above.
2.Press the override switch a number of times equal to the Disarm code, and continue holding for
10 seconds on the last press.
·
The system will disarm. If the code is entered incorrectly, turn off the ignition and begin
again.
To set the Emergency Override Code:
1.Turn on ignition.
2.Within 5 seconds, press the valet switch 5 times.
·
The siren will provide one long chirp, indicating that you have entered Programming.
3.Press the valet switch 3 times.
·
The siren will chirp each time the valet switch is pressed.
4.Within 5 seconds, press Button 3 on the transmitter.
·
The siren will chirp 3 times.
5.Press the valet switch the number of time equal to the desired code (from 1-15).
6.Turn off the ignition then arm the system.
7.Disarm the system using the new Override Code to permanently store the new code.
Note: If the code set procedure is not properly performed, turn off the ignition and begin again. The
override code will not be permanently stored until the code is used to disarm the system.
Summary of Contents for AS62UG
Page 1: ...AS62UG INSTALLERS INSTRUCTIONS ...
Page 10: ...AS62UG Not Used ...