19
Install Actuator Mounting Tube - PUSH TO OPEN
Cut Actuator Mount Tube to proper length. Weld to support bracket.
(
See table below for desired dimensions.)
The actuator mounting tube will need to be cut so that the ⅜” hole location matches the dimensions
for a push to open system.
Before welding in place, ensure the actuator
mounting tube is level in all directions and ⅜”
pivot hole location on actuator mounting tube is
at proper point per the dimension chart for the
type of installation being performed.
7”
Dim A
4”
Dim B
Cut Line
PUSH TO OPEN - Actuator Hinge Mounting Tube Installation Dimensions
Gate opening in degrees
Dimension A
Dimension B
90 degree opening
7”
4”
100 degree opening
8.5”
4”
6b
* Dimensions shown are
for 90° - 95° opening.
7”
Dim A
4”
Dim B