25
13
Set sontrol board DS1 dipswitches as follows for the installation:
Control Board Dipswitch Settings for Installation
DS 1 switch 3
OFF – press down on the left hand side
DS 1 switch 4
OFF – press down on the left hand side
DS 1 switch 6
ON – press down on the right hand side
Install the photo eye at this time. Once battery is installed, verify alignment.
Monitored Contact Edge (Type B2) Installation
for Entrapment Protection ONLY.
Connect wires per the table below: All wiring should be done with power disconnected from
control board.
Contact Edge wiring for Entrapment Device Protection
Contact Edge Connectons
Ranger Control Board Connections
N/O connection
J2 pin 6
Common
J2 pin 2 or pin 7
Install Battery
The recommended battery for all installations is a 12 volt Group
U1 maintenance free battery, 30 to 35 amp hours. This type
battery is commonly known as a lawn tractor or wheel chair
battery.
The charge controller harness is supplied with two ¼” ring
terminals for connection to the battery.
Connect the red wire to the positive post of the battery and the
black wire to the negative post of the battery as shown.
Connect the actuator 2 wire connector (or connectors if dual gate)
to battery harness.
NOTE:
DO NOT PLUG ACTUATOR(S) INTO
CONTROL BOARD AT THIS TIME.
12
b