44
7 Day Timer
(Solar friendly device)
Part Number 550015
The optional 7 day timer can be used to open the gate at a preset time and
if the auto close feature of the gate operator is being used the gate can
then close automatically at a preset time. The timer is supplied with 3 spade
terminals for easy connection. Connect wires from timer to control board J2
connector as follows:
• J2 Pin 1 (+12vdc) connect to pin 1
• J2 Pin 2 (Gnd) connect to pin 2
• J2 Pin 9 (Normally Open) connect to pin 4
Photo Eye
-
Vehicular Protection Only
Part Number 550010
Wiring Photo Eye to Ranger Control board
(Control Board part #500510 only)
Photo eyes are recommended for all gate installations to provide
safety and protect objects that might be in the gate path. Typically
a swing gate needs two sets of photo eyes for the best area
protection (see figure).
One set of photo eyes pointing across the drive on the outside of
the hinge post (A). The second set mounted across the drive at
the point where the gate is fully opened (B). The photo eye must
be installed where the gate does not break the beam.
The primary unit (Receiver) should be
installed close to the control box.
It requires 4 wires to be installed from
the unit to the control box.
The second unit (Transmitter) should
be installed on the opposite side of
the drive.
It requires 2 wires to be installed from
the unit to the control box.
The two units must face each other
to establish the beam (maximum
distance 40 feet).
The Photo Eye Power Management software installed in the control board makes it possible to power
photoeyes without pre-maturely draining the battery.
When utilizing the PEPM software the photo eye will only be powered up when the gate is about to
close or traveling in the closed direction. The PEPM software allows the gate to be held open without
battery drain and does not require any additional solar panels.