53
Photo Eye N/C contact monitoring -
1. Verify that DS1 dip switch 6 is ON press down on the right hand
side.
2. Verify that dip switch DS1 switch 9 (photo eye monitor) is ON press
down on the right hand side.
3. Turn dip switch DS1 3 and 4 OFF. Allows power to be applied to
photo eye.
4. Press and hold the LED indicator button located on the control
board.
5. Verify that LD6 LED (Photo eye N/C 2nd entrapment) located bottom
left corner of the control board is ON.
6. If not verify alignment between photo eye transmitter and receiver.
Correct if necessary.
7. If not then check wire connection from photo eye for proper
connection.
8. If LD6 is ON verify that the LD6 Led goes OFF when photo eye
beam is broken.
9. If LD6 does not turn OFF when beam is broken then photo eye is
bad.
4. My gate will not
automatically close
NOTE:
If DS1 switch 1 is on then the gate should automatically close
from any position.
1. Locate the “Open/Close Command “ push button. Press the button
to verify that the gate will close. If gate closes correctly then proceed
to the steps below.
2. Verify that DS1 switch 1 is on. If not, turn it on and recheck gate
operation. If gate remains open, continue with step 3.
3. If your installation is a single gate, then only DS1 switch 3 or 4 can
be on. If both are on the gate will not automatically close. Turn off
the one that is not being used and recheck gate operation.
4. Locate the “LED Indicator” push button and depress and hold. While
pushing the button inspect the LED indicators located on the control
board (under the J2 Terminal Plug) and note which LED’s are on. If
any LED’s are on disconnect the green J2 connector from the control
board. Press the “Open/Close Command “ push button to close the
gate. Press the button again to open the gate fully and verify the
automatic close is working.
5. If gate automatically closes correctly, then the accessory connected
to the J2 connector that is activated (LED is on) needs to be
repaired.