23
DS2 Function Dip Switches
ON - Down on right
OFF - Down on left
Switch
Setting Factory Settings are shown in bold type
1
Solenoid Lock Enable /
Gate in Operation Indicator /
Gate Leaf Delay
ON
To enable one of the following functions:
• Solenoid lock output energizes half second
before gate begins to move and releases 3
seconds after the gate begins to move.
• For gate in operation indicator to operate DS1
SW 5 must also be ON.
(Solenoid Lock Output =
+12 vdc / 1.5 amp max while gate is in motion)
• Gate Leaf Delay (
gate 2 delays 2 seconds)
OFF
Solenoid lock / gate in operation indicator /
gate leaf delay is inactive
2
Magnetic Lock Enable
ON
Magnetic lock output energizes on Close Limit and
releases half second before gate begins to open.
(Energizes = +12 vdc output 1.5 amp max)
OFF
Magnetic lock output is inactive
3
Security Shunt Circuit Enable /
Open Gate Indicator
ON
Security shunt circuit relay is active (closed circuit)
(wire in parallel) Relay activates half second before
gate begins to open and stays activated until 3
seconds after gate reaches a closed limit
OFF
Security shunt circuit relay is inactive (open
circuit)
4
Contact Edge Monitor
(must be ON when in pre 2016
mode for secondary entrapment
device operation connected at J2
pin 6.)
ON
Monitored contact edge is installed
OFF
No monitored contact edge installed
DS2 Switches