18
Limit Switch Adjustment
The limit switch adjustments are located on the bottom of the actuator. Remove the dust plug to make
adjustments. Flat blade screwdriver is included with the operator.
If soft stop is going to be used turn dipswitch 6 or 7 (see page 20) on at this time. Prior to operating the gate the
actuator extension tube needs to be turned 6 turns in the counter clockwise direction. Disconnect from gate
bracket to turn.
NOTE:
ALL ADJUSTMENTS SHOULD BE MADE IN THE MID TRAVEL (1/2 OPEN) POSITION. DO NOT
FORCE THE ADJUSTMENT; FORCING WILL DAMAGE THE LIMIT ASSEMBLY. REMOVE THE
ADJUSTMENT TOOL AFTER EACH ADJUSTMENT.
NOTE: For adjustment purposes only you might find it easier to flip the actuator upside down to
access the limit switch adjustment screws. Once adjustments are completed flip the actuator back to
the correct final installation position, see page 8 figure 6.
The following will assist you. Shown below are adjustments for pull to open and push to open installation.
Pull to Open Installation Only
To extend more or close gate more.
Turn the extend adjust clockwise.
To extend less or close gate less.
Turn the extend adjust counter clockwise.
To retract more or open gate more.
Turn the retract adjust clockwise.
To retract less or open gate less.
Turn the retract adjust counter clockwise.
Push to Open Installation Only
To extend more or open gate more.
Turn the extend adjust clockwise.
To extend less or open gate less.
Turn the extend adjust counter clockwise.
To retract more or close gate more.
Turn the retract adjust clockwise.
To retract less or close gate less.
Turn the retract adjust counter clockwise.
Bottom view of Actuator
RETRACT
EXTEND
Extend limit shaft
Retract limit shaft
Limit Nut
Limit Adjustment slots
Top of Actuator
White close limit wire
Orange open limit wire
Green common