27
TROUBLESHOOTING SECTION
OUTLINE
1 Single gate will not operate.
2 Dual gate will not operate.
3 Single or Dual gate opens or closes slowly.
4 Gate will not automatically close.
5 Gate begins to open or close, but stops and reverses after a couple of seconds.
6 Single Gate opens correctly then closes immediately or single Gate closes correctly and then opens
immediately.
7 Dual Gate opens correctly then closes immediately or dual Gate closes correctly then opens
immediately.
8 Control board 15 amp fuse blows when “Open / Close Command” is given.
9 Transmitter (Remote control) will not operate the gate. (Multi-Code/Digi-Code and Low current
receiver models)
10 Photo eye, safety loop or other safety accessory will not reverse the gate when closing.
11 Pressing the “RESET” button only, causes the gate to operate.
12 Gate opens with the transmitter but will not close with the transmitter
13 Gate only operates when the “LED INDICATOR” is pressed.
Terms and Definitions
LED -
Light Emitting Diode - small red lights on control board.
Control board- Located inside the metal box just above the battery.
Receiver -
Located inside the metal box in the upper right corner - coax cable connected to it.
Transmitter -
Hand held push button, which is used to operate the gate - sends signal to receiver.
Actuator -
Connected to gate and hinge post - contains the motor, gearbox and extension tube.
Connector -
Control board has two types of connectors. Two white 8-pin connectors (X1 and X2) are
used to connect actuator to control board and one green 12-pin connector (J2) (located
bottom center of control board) to connect receiver and accessories to control board. Both
are plug type and can be disconnected (unplugged from control board) without
disconnecting wires.
Dip Switches - Small switches, which are located on the control board in two places. The primary set DS1,
is located in the upper left corner and the secondary set DS2, is located in the lower right
corner of the control board with functions listed beside each. See manual (page 20, 21) for
more information.
Push Buttons - Three are located on the control board. “Open / Close Command” used to operate the gate,
“LED Indicator” used to activate the LED’s and “Reset” used to reset the control board
after current sensing twice before a limit is reached.