STEP 2a Hinge Mount Tube Installation
(Push to Open Installation Top View)
Use dimensions in figure 3 to determine mounting location of Hinge mount tube, cut hinge mount tube as
necessary to achieve correct mounting dimension.
Regardless of method used, the hinge mount tube should be very secure since the entire force of the gate is
directed to this mount. The post must be of adequate strength to resist twisting as well.
STEP 3 Hinge Mount Tube Installation
(Vertical Height Positioning)
NOTE: The gate bracket vertical mounting location on the gate must be determined before installing
the hinge mount tube.
The approximate distance from the hinge to the gate bracket mounting
position is 55”. The exact location will be determined on page 8 or 9 under gate bracket
installation step 3 or 4 depending on the installation type.
Now that the type of installation (Pull to Open or Push to Open) has been determined the vertical height
position of the hinge mount tube must be determined. Refer to page 9 figures 9 - 9D to help determine the
mounting location of the gate bracket, which is needed to determine the location of the hinge mount tube.
Once the approximate gate bracket location is determined mark the center point of the gate bracket location
on the gate.
Using a level, determine the centerline point on the gatepost that is level with the gate bracket centerline
mark made previously. Mark the gatepost centerline point, see figure 4.
The topside of the hinge mount tube will be installed 5/8” below the centerline mark on the gatepost.
Measure down 5/8” below the centerline point and mark the gatepost, see figure 4.
Before welding in place ensure that the hinge mount tube is level in all directions.
NOTE: The top side of the hinge mount tube must be installed 5/8” below the centerline of the gate
bracket. This will ensure that the actuator is level when installed.
NOTE: The ½” hole in the hinge mount tube is the pivot point for the actuator rear adapter, it must
be correct for proper operation. Before welding in place verify dimensions in figure 2 or 3
depending on installation type.
Once location of hinge mount tube is verified weld in place.
Level
Figure 3
Gatepost
Gate Bracket
5/8 inch
Center Line
Hinge mount tube
Figure 4
OPEN DIRECTION
GATE
6”
11”
Gatepost 4” steel shown
¼” wall
Hinge mount tube cut as necessary to
achieve dimension needed.