27
17. Cut extension cable to length allowing for future considerations.
18. Remove 2” of cable insulation to expose the 5 wires.
Caution: do not damage internal wires.
19. Remove approximately 1/2” of insulation from each wire.
20. Locate 8 pin connector and pigtail previously cut from Gate 2 linear
actuator cable. Prepare wires for the splice.
21. Connect the 5 wires from extension cable to the 5 wires from the pigtail
by matching the wire colors. Then secure with supplied wire nuts.
22. Roll cable and place in wire compartment.
23. Install junction box cover and securely snap in place.
Connecting Gate 2 Linear Actuator to Control Board
1. Locate the power connector attached to the linear actuator cable (red and black wires).
2. Connect it to the remaining Plug N Go harness linear actuator power plug. These connectors are
designed so that incorrect connection is not possible and it does not matter which connector is
used.
3. Locate the linear actuator cable 8 pin plug. Connect it to the Gate 2 connector located on
the Sentry Control board adjacent to the Gate 1 connector. Securely snap in place. Once all
connections are made place wires in wire compartment.
Preparing to Operate Gate 2 for the First Time
Using the “Open/Close Command” button on the control board open Gate 1. This is done because
Gate 2 was just installed in the open position and now both gates should be in the open position.
Operating Gate 2 for the first time and final adjustments
1. Locate the control switches and turn on switch 4 (press down on the right side).
2. Gate 1 and Gate 2 should be in the open position if installed correctly.
3. Press the “Open/Close Command” button to close Gate 1 and Gate 2.
4. Gate 2 limit adjustment has not been made so it should stop short of fully closed.
5. Turn “OFF” control switch 3, disabling Gate 1.
6. Now use the “Open/Close Command” button to cycle Gate 2 and adjust Gate 2 close limit
to match Gate 1 close position.
7. With both gates now closed, turn “ON” control switch 3 enabling Gate 1.
8. Press “Open/Close Command” to open both gates and then close, adjust limit positions if
necessary.
CAUTION:
To reduce the risk of injury, USAutomatic strongly recommends the installation of
additional safety devices such as Photo Eye Sensors and Safety Edges. Consult an authorized
installing dealer or www.Sentrygateopener.com for a complete explanation of options and see
the Safety Section of this manual on pages 3 to 4.